Waterschap Brabantse Delta · Predictive Maintenance · research artifact
The frozen package contains 43,200 one-minute slots from 30 September 2026 11:35 UTC to 30 October 2026 11:35 UTC (exclusive), seven-day model history, 3,757 stable model/measurement pairs, 160 run segments including 139 complete cycles, and 988 long-term day rows. Minute data originate from Z-info via FROST and the EVOLV API. The model history is a separate collector view: it is not interchangeable with the FROST series.[1][2]
Corrections to the initial chat analysis: +14 cm is a peak, not a sustained plateau; 160 run segments are not 160 verified starts; the common FT001 cannot be treated as two separate pump flowmeters; effective area below the inlet does not establish upstream sewer storage; and a raw API link was not a usable graph reference. Figures and immutable SQLite rows in this artifact replace those references.
The selected period is a convenient case study, not a random sample. High-load operation is mostly P100; P200 has no comparable high-flow band in the stable seven-day sample. No rainfall, downstream water level, temperature, vibration or independent reference flow was acquired. Weather, wear and thermal explanations therefore remain hypotheses. Sources are dated; source hashes and calculation code are embedded.[1][2]
SELECT t,local,clean_level,flow,pump,zero_invalid FROM minutes ORDER BY tQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
Observation The highest available FROST minute value is −1.69 m NAP at 25 October 03:01 CET (02:01 UTC), 14 cm above the documented −1.83 m NAP crest. Exactly one available one-minute bin reaches that rounded peak, and two reach at least +13 cm. That does not establish a one-minute physical peak duration: values are minute averages and the preceding period contains a gap.[1][3]
There are 80 available minute values strictly above the crest on 24 October and 59 on 25 October: 139 minute-equivalents in total. Values exactly on the crest are not counted. This differs from the earlier 218 count from the separate twin view and its ≥ test. The FROST evidence is primary here; the twin snapshot remains downloadable for reconciliation. Missing values prevent a defensible exact duration, peak or full-event volume.[1][2]
| Local date | Day length (min) | Valid level bins | Above crest | ≥ +10 cm | ≥ +14 cm | Observed peak |
|---|---|---|---|---|---|---|
| 2026-10-24 | 1440 | 902 | 80 | 19 | 0 | 12 cm |
| 2026-10-25 | 1500 | 1087 | 59 | 13 | 1 | 14 cm |
SELECT t,local,clean_level,flow,rpm100,rpm200 FROM minutes WHERE day IN ('2026-10-24','2026-10-25') ORDER BY tQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
SELECT day, SUM(clean_level > -1.83+0.000001) AS above_crest, SUM(clean_level >= -1.73-0.000001) AS ge_10cm, SUM(clean_level >= -1.69-0.000001) AS ge_14cm FROM minutes WHERE day IN ('2026-10-24','2026-10-25') GROUP BY dayQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
Actual discharged volume remains unidentified. The owner confirmed that crest geometry and downstream conditions are not yet known; they can be supplied later. Crest width, crest shape, local hydraulic connection between LT001 and the crest, downstream submergence and missing levels are not verified. A wet-well level above a design crest is evidence of potential exposure, not a measured discharge.
| Qₒ | Conditional free overflow rate | m³/s | Rectangular-weir scenario [8] |
| C | Assumed discharge coefficient | m½/s | Default 1.7; explore 1.4–1.9, not calibrated |
| b | Assumed crest width | m | Unknown; slider is a scenario |
| h | Head over crest | m | LT001 minus crest, assuming hydraulic equivalence |
| z | Water level | m NAP | FROST LT001 [1] |
| z꜀ | Crest elevation | m NAP | −1.83 from maatgeving; verify [3] |
For C = 1.7 and one metre of free rectangular crest, summing the available level-bin estimates gives approximately 195 m³ over 24–25 October. Filling only internal gaps of at most five minutes by linear interpolation changes this scenario to about 220 m³ per metre; long gaps stay unknown. Neither value is a lower confidence bound or a measured total: nonlinearity within a minute, geometry and downstream level are unresolved. At the observed 14 cm head, the same assumed crest passes approximately 321 m³/h per metre. A ±2 cm change in crest reference changes the observed-bin estimate from roughly 124 to 297 m³ per metre. This sensitivity is larger than the precision suggested by a single volume number.[1][8]
SELECT t,local,clean_level FROM minutes WHERE day IN ('2026-10-24','2026-10-25') ORDER BY tQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
Physical candidate On 19 October 07:01–07:05 CEST, FT001 reports −73.9, −157.5, −141.0, −136.3 and −126.5 m³/h while both speeds indicate stopped pumps. The integrated indicated reverse volume is 10.59 m³. PT001 briefly reads −80 mbar and the level rises from −4.20 to −4.06 m NAP. The sequence follows a P100 run. On 20 October 04:24–04:27 CEST a smaller negative-flow sequence follows P200 operation.[1]
The concurrence of signed flow, pressure collapse and a rising well makes a hydraulic transient/reverse-flow explanation worth testing. A non-sealing or delayed check valve, an air-vessel transient or oscillatory flow near the transmitter are candidates. Sensor direction/scaling and timestamp alignment must also be checked. Minute averages cannot resolve water hammer; no check-valve failure is proven. Small negative offsets around −1.8 m³/h recur at many stops and must not be equated with the much larger 19 October event.[1][3][10]
SELECT t,local,level_nap,flow,pressure,rpm100,rpm200 FROM minutes WHERE t BETWEEN '2026-10-19T04:50:00Z' AND '2026-10-19T05:20:00Z' ORDER BY tQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
P100 and P200 share FT001 and PT001. At low flow, stable matched bands (210–230 m³/h) give approximately 845 versus 857 rpm, 13.21 versus 14.09 kW indicated power, and almost the same header-to-well head: 14.31 versus 14.39 m. Mean model flow is 211.95 versus 221.74 m³/h against measured 220.08 versus 219.96 m³/h. Mean active motor current is approximately 65.88 versus 66.48 A: much closer than the indicated kW. Current alone does not establish input power or efficiency without voltage, power factor and register mapping. There are 663 and 632 flow pairs respectively; power and current use only their available subsets.[2]
A flowmeter error is possible, but not uniquely or most probably established. A shared calibration gain affects both pumps. Pump-dependent upstream swirl or velocity profiles could make the same meter respond differently to each branch, depending on its installation. Lower actual branch losses can also explain lower required speed and power at the same real flow. Differences in motor/drive calibration, efficiency, wear or impeller condition remain alternatives. These are identifiability limits, not equally supported diagnoses.[3][7][9][10]
The current model uses the same loss coefficient for both branches: 1.6451 × 10⁻⁵ m/(m³/h)². Its pump-axis height cancels out of the net static head; a 20 mm axis difference does not explain the bias. Under the joint assumption that the type curve, FT001, speed and PT001 are correct, the low-flow data imply median internal losses of about 0.44 m for P100 and 0.89 m for P200. At high P100 flow, implied loss is about 1.24 m against 2.65 m in the model. Branch-specific loss calibration is therefore a concrete competing explanation. It is not an independent measurement of pipe losses.[2][4]
SELECT t,pump,rpm,qMeas,head,head_external,required_loss FROM steady ORDER BY tQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
SELECT t,pump,qMeas,qModel,pMeas,eModel FROM steady ORDER BY tQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
SELECT t,pump,qMeas,required_loss,required_k,loss FROM steady ORDER BY tQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
SELECT t,pump,regime,bias,rpm,lv,pt,head,head_external,pMeas,CASE WHEN pump='P100' THEN i1 ELSE i2 END AS active_current FROM steady ORDER BY tQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
The historical SAT check is not a direct calibration target until head conventions are aligned. At low speed the type curve predicts roughly 226 versus 225 m³/h for P100. At its 1,300 rpm SAT point it predicts 493 versus 442 m³/h (+11.6%); other high-speed SAT differences are about +6–7%. In contrast, the current complete hydraulic model generally underpredicts P100. A global flow correction would obscure the distinction between pump curve, installation losses and metrology.[3]
The inlet reference in the available ground truth is −3.80 m NAP. This is treated here as the documented inlet invert (BOB), not a verified pipe crown (BOP). Below an inlet invert, a freely discharging inlet does not provide directly communicating upstream storage at the wet-well level. Above the invert, partial-pipe storage/backwater may begin; the crown alone is not the onset of all network storage. Actual connectivity, invert and pressure conditions must be checked.[3][10]
Conditional calculation Of 136 complete cycles with a valid area estimate, 134 remain below −3.85 m NAP throughout the available 12-minute pre-run/run/post-stop level window. Their median effective area is 104.55 m² (middle half 96.48–109.48 m²). Missing level samples are not proof of the condition between observations; this is an available-sample screen. The discrepancy survives a 5 cm margin below the documented invert.[2]
The data do not establish five times more sewer storage. With 20.7 m² and the median observed slopes, inflow would be about 12 m³/h before pumping and 185 m³/h during pumping. Alternatively, assuming unchanged inflow and 20.7 m² would require real flow of only about 19.5% of FT001. This large inconsistency warrants checking the current wet-well geometry, level scaling/reference, actual inlet elevation/connectivity and correlated inlet variation. A shared flow bias of a few percent cannot explain a factor-of-five area mismatch.[2][3]
| A | Effective storage derivative dV/dz | m² | Inferred, constant over fitted window [2,4] |
| Qₚ | Pumped discharge; zero when truly stopped | m³/h | FT001 [1,2] |
| s_off, s_on | Fitted level slopes before/during pumping | m/h | Least-squares fits in cycle algorithm [4] |
| Qin | Inflow inferred by mass balance | m³/h | Requires known A and no other outflow |
| z,t | Level and elapsed time | m, h | LT001 and UTC timestamps |
| Conditions | Equal inflow for the area inversion; no overflow, reverse flow or unaccounted connected volume | — | Explicit assumptions, not measured facts |
SELECT id,start,pump,area,below_margin,max_level_window FROM cycles WHERE complete=1 AND area IS NOT NULL ORDER BY startQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
SELECT * FROM cycles WHERE complete=1 AND area IS NOT NULL ORDER BY startQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
SELECT id,pump,riseOff,fallOn,flowMeas,area FROM cycles WHERE complete=1 AND below_margin=1 AND area IS NOT NULLQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
Reverse-engineering the sewer requires another independent constraint. During a pump-off, non-overflow period and with known storage, inflow can be inferred from the rise; it is still inferred, not directly measured. Above the inlet, the single equation contains two unknowns—Qin(t) and Aeff(z). The same level/flow trace cannot uniquely determine both. A useful next experiment is a bounded alternation of pump-on and pump-off periods with slowly varying inflow, surveyed wet-well geometry, upstream level and ideally an inlet flow reference. Then fit a piecewise storage curve, validate on held-out cycles, and propagate flow/level errors. Do not extrapolate the low-level 105 m² fit into the high-water/overflow range.[4][10]
Two meanings of “opschakelen” need separate accounting. Increasing running speed changes head, flow and specific energy. Starting another pumping cycle adds a short ramp/transient and affects mechanical duty. Neither cost can be inferred solely from the number of starts.[2][10]
For P100 stable minutes with power available, low-flow operation averages 220.5 m³/h, 13.26 kW and 60.15 Wh/m³. High-flow operation averages 413.8 m³/h, 39.74 kW and 96.06 Wh/m³: about 36 Wh/m³ more (+59.7%), or an arithmetic 36 kWh per 1,000 m³ at those observed operating points. It is not an achievable saving: high flow occurs at much higher head (~25 versus 15 m) and may be needed to avoid flooding. The cubic speed law alone is not a site-energy estimate when static head and efficiency change.[2][10]
SELECT pump,regime,COUNT(*) AS n,1000*SUM(pMeas)/SUM(qMeas) AS wh_m3 FROM steady WHERE pMeas IS NOT NULL GROUP BY pump,regimeQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
In 58 adjacent low-flow cross-pump cycle comparisons (within two hours, mean flow within 5 m³/h, model head within 0.3 m), P200 has a median +11 rpm, +0.12 m model head and +3.1 Wh/m³. These pairs can reuse a cycle; they are a descriptive cross-check, not 58 independent experiments. This comparison supports a persistent branch/pump measurement difference even after reducing operating-condition mixing.[2]
For 112 complete low-flow cycles with all required power minutes, the first two-minute energy minus a same-cycle steady Wh/m³ baseline has median 0.087 kWh, with the middle half 0.011–0.114 kWh. This is a transient-associated proxy, not isolated motor-start energy: the 30-second start at 50% command is blurred by minute averaging, pressure/storage change during the start, and the baseline assumes equal steady energy per unit volume.[2][3]
SELECT start,pump,incremental_kwh,baseline_wh_m3,minutes FROM startup ORDER BY startQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
| fstart | Station starts per 24 hours | day⁻¹ | Ideal constant-flow fill/drawdown cycle |
| A | Constant effective area | m² | Scenario; not accepted geometry |
| Δz | Start minus stop level | m | Observed 0.284; Cordis 0.3645; design 0.68 [2,3] |
| Qin, Qp | Constant inflow and pumping rate | m³/h | Scenario, with 0 < Qin < Qp |
| 24 | Hours in the hypothetical comparison day | h/day | Typical 24-hour scenario; not DST-day aggregation |
At unchanged area and flows, a 0.284 m deadband implies about 2.39 times as many cycles as a 0.68 m band. Moving to 0.3645 m would reduce the ideal start count by about 22%; moving to 0.68 m by about 58%. These are geometric scenarios. Deeper drawdown also raises suction lift, can change air entrainment/NPSH and increases average pumping head; permitted levels and inlet conditions must be verified first. No PLC settings were changed.[2][3][10]
SELECT start,pump,incremental_kwh FROM startup ORDER BY startQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
The metric is NRMSE (normalized root mean squared error). It measures model disagreement, not a probability of failure. The deployed EVOLV pin is 9fcabe7f…; its generalFunctions and rotatingMachine submodule sources are embedded at their pinned commits, not assumed from a newer checkout.[4][5]
| ŷᵢ, yᵢ | Predicted and measured flow/power | Same units | Native model measurement windows [5] |
| N | Paired samples in short-term window | count | Up to 30 per pump and metric [5] |
| ymax − ymin | Normalization range | m³/h or kW | Current model prediction surface range; fallback to available values [5] |
| Lₜ | Stored long-term NRMSD field | dimensionless | EWMA of nonnegative short-term NRMSE, not signed bias [5] |
| α | EWMA gain | — | 0.15; long-term readiness after 10 samples [5] |
| t | Update index | count | Model assessments, not calendar days |
“Long term” here does not mean 30 days. The short-term window is 30 samples; the EWMA has a half-life of about 4.27 updates, applied to already-windowed errors. Ten samples enable its mature output. Updates can be sparse or stop during pump-off periods, so neither is a fixed clock-time window. The exported seven-day history omits the normalization bounds, sample counts, reset events and the native long-term power series. Those missing fields prevent exact independent reconstruction of every native point.
Short-term default thresholds are 5%, 10%, 15%; long-term thresholds are 2%, 4%, 6%, using strict “greater than” comparisons. Thus a persistent 7% discrepancy can be “low” immediately and “high” long term without growing over time. Bias can also cancel while RMSE stays high, and changing the normalization range can change NRMSE even when error in m³/h is unchanged. Confidence values around 0.5 are internal scores, not a calibrated 50% probability that the pump is sound.[5]
SELECT t,mp,r1,r2,efn,native_flow_ewma,native_flow_level,epn,econf FROM history WHERE efn IS NOT NULL ORDER BY tQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
| Pump | Flow regime | Available stable rows | Median flow NRMSE | Median flow EWMA | Median power NRMSE | Rows with flow EWMA >6% | Native bias (m³/h) | Shadow bias, same rows (m³/h) |
|---|---|---|---|---|---|---|---|---|
| P100 | low | 301 | 6.50% | 6.40% | 7.10% | 66.4% | -7.94 | -8.01 |
| P100 | medium | 141 | 3.70% | 3.80% | 11.00% | 17.0% | -19.45 | -19.91 |
| P100 | high | 404 | 4.20% | 4.20% | 11.85% | 3.0% | -24.78 | -25.79 |
| P200 | low | 269 | 7.30% | 7.30% | 6.60% | 75.8% | +1.97 | +2.01 |
| P200 | medium | 64 | 1.20% | 2.30% | 5.75% | 23.4% | -5.65 | -6.11 |
A useful inconsistency: P200 at low flow has only about +1.97 m³/h mean instantaneous native flow bias on these rows, yet its median native flow NRMSE is 7.3%. P100 low flow has −7.94 m³/h bias and 6.5% median native NRMSE; at high flow its bias grows to −24.78 m³/h while median native NRMSE drops to 4.2%. Thus the native percentage is not simply the current error divided by current flow. The dynamic normalization range, rolling window, transients and update history can all influence the ranking. Missing per-point normalization bounds prevent attribution among them. Do not rank pump condition directly by these percentages. On the same available rows, instantaneous native and shadow mean biases are close; their windowed diagnostics still answer different questions.[2][5]
SELECT t,pump,regime,evq-qMeas AS native_signed_error,efn,native_flow_ewma,bias AS shadow_signed_error FROM steady WHERE evq IS NOT NULL AND efn IS NOT NULL ORDER BY tQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
SELECT t,pump,rmse30_fixed_pct,ewma_fixed_pct,bias30_pct FROM steady ORDER BY tQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
For maintenance monitoring: retain raw error in engineering units, signed bias, explicit normalization bounds, sample count, operating regime, quality flags and model/configuration version. Compare each pump against its own validated branch baseline, then compare their residual changes under matched conditions. A persistent offset is a calibration question; a change within the same validated regime is a stronger deterioration signal. Both still need independent inspection.
The long-term chart ends on 19 October 2026; its “last 30 days” are not the same window as the current week. It contains 988 calendar rows from 2024, but valid energy increments start on 9 April 2025. The “energy since start” sum therefore must not be described as complete energy since renovation. The latest 60-day lower envelope is about 14.44 kW for P100 and 15.01 kW for P200. Within 2026 this does not establish a monotonic degradation trend; operating mix, resets and availability still matter.[6]
The historian provides daily means of cumulative counters, then the application differences those means. These are not exact midnight-to-midnight meter deltas; fractional start counts expose the averaging. Quality metadata record 13/12 energy resets and 50/44 hours-counter resets for P100/P200, plus rejected steps. Filtered sums and ratios should use the intersection of valid energy and runtime days. No valid range can repair an incorrectly defined source counter.[6][4]
SELECT day,kw14_100,kw14_200,floor100,floor200 FROM longterm ORDER BY dayQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
What “Emotron” means here: it is the variable-frequency drive. An official FDU-family manual distinguishes a shaft-power output [714] from an electrical output-power signal [715]; it also has an energy counter [733]. That establishes that several different quantities exist. It does not establish which register the Klundert PLC exports as Meting.Vermogen, nor that this older reference manual matches the installed firmware. The tag mapping and drive parameter number are still required.[11]
If the tag is shaft power, compare with model shaft power. If it is electrical power delivered by the drive to the motor, include motor losses but not drive input losses. If it is grid input power, include both. The current comparison includes motor losses and an assumed 97% drive efficiency. Its −8% bias cannot be interpreted as actual energy loss until these measurement boundaries agree. The site tag is therefore called indicated power throughout this artifact; cycle integrals inherit that uncertainty.[3][4][11]
Implemented in this artifact Raw records remain intact in SQLite. A separate flag excludes the six records where LT001 = 0 m NAP and flow, pressure and both speeds simultaneously equal zero. This is a station-specific coherence rule supported by rapid return to normal surrounding levels, not a generic “delete zeros” rule. Negative flow, pump-off zero flow, flat setpoints and real high levels are retained. Each graph’s SQL and exclusions remain inspectable.[1]
Other rules should mark suspect data rather than silently replace it: source bad-quality codes; impossible physical ranges after unit conversion; time misalignment; duplicate event times; counters going backwards; implausible isolated jumps; and saturation/stuck values only when corroborated by other channels. The acquired chart API does not expose all original historian quality codes, so this artifact cannot retrospectively apply those tests. Interpolation is never treated as observation. Derived model/drift/energy results need their own validity masks.
SELECT t,local,level_nap,clean_level,flow,pressure,zero_invalid FROM minutes WHERE t BETWEEN '2026-10-20T08:05:00Z' AND '2026-10-20T08:18:00Z' ORDER BY tQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
SELECT day,expected_minutes,window_minutes,flow_minutes,level_minutes,missing_flow FROM daily ORDER BY dayQuery the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.
Confirmed timestamp mechanism: the historian adapter rejects offset-free local timestamps that map to two Amsterdam instants. On 25 October, local 02:00–02:59 occurs twice (UTC 00:00–00:59 and 01:00–01:59). A response containing only a wall-clock label cannot identify the occurrence. The raw API reports a gap spanning this region. That code behaviour explains a credible mechanism; the missing source payload itself was not available to prove the provenance of each absent minute.[4]
Correct resolution: keep UTC event coordinates, show the local offset on hover, identify the repeated-hour interval, count 1,500 minutes for the day, and require an explicit UTC/offset or trustworthy occurrence/order metadata from the source. Historical values can only be restored by re-reading an unambiguous source and performing a versioned backfill. Fabricating duplicate values or choosing one offset would create false evidence. The artifact implements the UTC representation, day-length calculation and missing-data annotation; historical recovery remains open.
Application follow-up: code-level corrections and rollout evidence are listed in the delivery record below. Artifact filtering is active independently of the live application.
The following matrix separates observations from mechanisms. No failure probability is assigned. P100/P200 identity and short separation remove some design variability but do not make branch loss, sensor response, wear state or motor setup identical. Physics mechanisms below are hypotheses to test, supported by the energy and hydraulic relationships and manufacturer measurement guidance.[7][9][10][11]
| Candidate | Evidence status | Why it is in scope | Test that distinguishes it |
|---|---|---|---|
| Different pipe-branch losses | High-priority competing hypothesis | Same K is used for both branches; P200 needs more speed at similar FT001/header conditions. | Pump-flange suction/discharge pressure plus matched-flow runs; survey fittings/valve openings. |
| FT001 gain or branch-dependent profile | Plausible; not ranked above branch losses | Shared transmitter: common gain alone cannot explain pump-specific offset; changed inflow profile can. | Independent portable/reference meter, installation audit, direction and zero check. |
| PT001 offset / height / dynamic response | Plausible | Shared sensor; head and curve residual are strongly coupled; local sensor elevation is assumed. | Calibrate pressure, survey tapping elevation, synchronized flange reference. |
| LT001 scaling / zero / geometry | High priority for water balance | 105 m² inversion persists below the documented inlet; six cross-channel zero bursts. | Independent level reference at several heights, 4–20 mA/PLC scaling and wet-well survey. |
| Check-valve leakage / closing transient | Event-specific candidate | 19 October negative flow, pressure dip and rising level after P100 stops. | Valve inspection and high-rate synchronized signed flow/pressure around stops. |
| Impeller wear, ragging, clearance, rotation | Possible, no diagnosis | Identical nominal pumps can differ in condition; no matched baseline or inspection exists. | Inspection, impeller identity/trim, vibration and repeatable Q–H–P acceptance test. |
| Air entrainment / cavitation / suction restriction | Possible, unmeasured | Low suction submergence may matter; minute data cannot resolve pressure pulsation or NPSH margin. | Suction absolute pressure, liquid temperature, NPSHr curve, vibration/acoustics, vortex observation. |
| Motor heating / cooling / bearings | Unmeasured thermal hypothesis | Long P100 duty differs from short cycles; no winding, bearing or ambient temperature was acquired. | Temperature and vibration trend at matched hydraulic load; motor/drive thermal model audit. |
| Drive register / motor parameter mismatch | Priority metrology check | As-power and electrical-output registers exist; the site tag mapping is unverified. | Read parameter/register mapping, rated motor data, identification run and independent power meter. |
| Density / viscosity / solids / fouling | Possible but unconstrained | Water properties are assumed (998.2 kg/m³); no temperature/solids series is present. | Liquid temperature and solids; verify curve applicability and clean-water baseline. |
| Timestamp, quality, aggregation / counter resets | Observed data limitations | Repeated hour, zero bursts, sparse native output and different collectors produce different totals. | UTC provenance, quality flags, aligned windows, audited backfill and counter-reset events. |
| Model structure / dynamic normalization | Observed modelling limitation | Common branch K, uncertain power boundary and changing NRMSE range. | Versioned branch model, explicit measurement boundary, logged NRMSE denominator and residual baseline. |
Thermal limits: higher winding temperature increases copper resistance and losses; bearing friction and reduced low-speed cooling can change indicated power. Those mechanisms cannot be separated here because no temperature or loss measurements were collected. Motor current alone is not electrical power: voltage, phase/power factor, waveform and measurement boundary matter with a drive. Inferring temperature or motor efficiency from the 66 A signals would exceed the evidence. A higher observed power can also be the correct hydraulic response to higher head. The pinned rotatingMachine boot code seeds a 15 °C temperature value; this is a software default, not an acquired Klundert temperature measurement. It must not be presented as thermal evidence.[5]
Recommended order: (1) confirm crest/inlet elevations and inspect the reverse-flow event; (2) independently verify FT001, LT001, PT001 and drive power mapping; (3) alternate pumps at matched flow/level/header pressure and identify per-branch loss; (4) survey storage and fit an above-inlet network model using upstream level/inflow constraints; (5) establish a stable, versioned residual baseline before using drift for maintenance alarms. No operating setting, calibration or physical control has been changed by this analysis.
The presentation value is not “we diagnosed the pump from a month of data”. It is that a small dataset can locate concrete inconsistencies, distinguish measurable facts from assumptions, quantify conditional effects, and specify the next measurement that will resolve each competing explanation.
The database and SQL engine are embedded in this HTML. After loading the artifact, figures query the browser-local database; no EVOLV API is called. The SQL explorer displays up to 200 rows; CSV exports the full query result. To reproduce the calculations, save the SQLite and reproduce.py together, then run python3 reproduce.py klundert-20261030.sqlite with Node.js and Python NumPy/pandas/SciPy installed. The helper verifies hashes, extracts source and pinned code into a new directory, regenerates the stable pairs and reruns the analysis. Raw API responses, their hashes and source URLs are in sources; calculation and pinned model code are in code.
The fixed history export lacks the native power EWMA, per-point normalization bounds, update counts and complete runtime reset trajectory. Empty fields remain empty. Raw source JSON is preserved alongside the normalized tables. Units: FROST level is metres above floor; level_nap = level − 5.05. History lv is already m NAP. pressure is mbar; power is indicated kW; Q is m³/h.