Waterschap Brabantse Delta · Predictive Maintenance · research artifact

Klundert: what one month reveals about a pumping station

WBD R&D · analytical investigation30 October 2026version 1.1evidence reviewed · field validation open
Two identical Hidrostal pumps, two different pipe branches, one shared flow transmitter. This investigation turns a small operational dataset into testable maintenance questions: overflow exposure, reverse flow, branch losses, storage, switching energy and model drift. Observations, conditional calculations and unresolved causes are kept separate. The owner's clarification that P100 and P200 are identical and approximately two metres apart is an input to the analysis, not a result inferred from the signals.[7]
139available minute bins above the crest, 24–25 Oct; incomplete coverage
1 binat the observed +14 cm peak; exact peak duration unknown
104.6 m²effective area in 134 qualifying cycles below the documented inlet
+60%P100 indicated Wh/m³ at high versus low flow; not a causal savings claim
Opening the embedded SQLite evidence package…

Evidence, scope and corrections

The frozen package contains 43,200 one-minute slots from 30 September 2026 11:35 UTC to 30 October 2026 11:35 UTC (exclusive), seven-day model history, 3,757 stable model/measurement pairs, 160 run segments including 139 complete cycles, and 988 long-term day rows. Minute data originate from Z-info via FROST and the EVOLV API. The model history is a separate collector view: it is not interchangeable with the FROST series.[1][2]

Corrections to the initial chat analysis: +14 cm is a peak, not a sustained plateau; 160 run segments are not 160 verified starts; the common FT001 cannot be treated as two separate pump flowmeters; effective area below the inlet does not establish upstream sewer storage; and a raw API link was not a usable graph reference. Figures and immutable SQLite rows in this artifact replace those references.

The selected period is a convenient case study, not a random sample. High-load operation is mostly P100; P200 has no comparable high-flow band in the stable seven-day sample. No rainfall, downstream water level, temperature, vibration or independent reference flow was acquired. Weather, wear and thermal explanations therefore remain hypotheses. Sources are dated; source hashes and calculation code are embedded.[1][2]

One month, two operating regimes

Raw FROST level and flow, with six simultaneous-zero records excluded from the analytical level series. High load on 23–25 October dominates the month. Negative flow is retained as a physical candidate, not clipped. All time coordinates remain UTC; hover labels include the Amsterdam offset. [1]
Data & reproducibilitySELECT t,local,clean_level,flow,pump,zero_invalid FROM minutes ORDER BY t

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

How long above the overflow crest, and how much water?

Observation The highest available FROST minute value is −1.69 m NAP at 25 October 03:01 CET (02:01 UTC), 14 cm above the documented −1.83 m NAP crest. Exactly one available one-minute bin reaches that rounded peak, and two reach at least +13 cm. That does not establish a one-minute physical peak duration: values are minute averages and the preceding period contains a gap.[1][3]

There are 80 available minute values strictly above the crest on 24 October and 59 on 25 October: 139 minute-equivalents in total. Values exactly on the crest are not counted. This differs from the earlier 218 count from the separate twin view and its ≥ test. The FROST evidence is primary here; the twin snapshot remains downloadable for reconciliation. Missing values prevent a defensible exact duration, peak or full-event volume.[1][2]

Available sample occupancy, not continuous event duration. 25 October contains 1,500 actual minutes because clocks go back. Missing slots remain missing. [1]
Local dateDay length (min)Valid level binsAbove crest≥ +10 cm≥ +14 cmObserved peak
2026-10-2414409028019012 cm
2026-10-25150010875913114 cm

The two crest exceedances and the missing repeated hour

Crest, high-water level and RWA level come from the current maatgeving snapshot. Dots are observations; gaps are not connected. The shaded repeated hour spans two distinct UTC hours; it is not compressed into one. The two observed exceedance clusters are around 24 Oct 00:24–02:43 CEST and 25 Oct 01:07 CEST–03:41 CET, with internal gaps. [1,3]
Data & reproducibilitySELECT t,local,clean_level,flow,rpm100,rpm200 FROM minutes WHERE day IN ('2026-10-24','2026-10-25') ORDER BY t

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

Threshold occupancy is not the same as peak duration

Number of valid one-minute bins above each height. Counts say how much of the available record is above a threshold; they do not fill missing intervals. [1]
Data & reproducibilitySELECT day, SUM(clean_level > -1.83+0.000001) AS above_crest, SUM(clean_level >= -1.73-0.000001) AS ge_10cm, SUM(clean_level >= -1.69-0.000001) AS ge_14cm FROM minutes WHERE day IN ('2026-10-24','2026-10-25') GROUP BY day

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

Actual discharged volume remains unidentified. The owner confirmed that crest geometry and downstream conditions are not yet known; they can be supplied later. Crest width, crest shape, local hydraulic connection between LT001 and the crest, downstream submergence and missing levels are not verified. A wet-well level above a design crest is evidence of potential exposure, not a measured discharge.

Qo=Cbh32h=max(z−zc,0)
QₒConditional free overflow ratem³/sRectangular-weir scenario [8]
CAssumed discharge coefficientm½/sDefault 1.7; explore 1.4–1.9, not calibrated
bAssumed crest widthmUnknown; slider is a scenario
hHead over crestmLT001 minus crest, assuming hydraulic equivalence
zWater levelm NAPFROST LT001 [1]
z꜀Crest elevationm NAP−1.83 from maatgeving; verify [3]

For C = 1.7 and one metre of free rectangular crest, summing the available level-bin estimates gives approximately 195 m³ over 24–25 October. Filling only internal gaps of at most five minutes by linear interpolation changes this scenario to about 220 m³ per metre; long gaps stay unknown. Neither value is a lower confidence bound or a measured total: nonlinearity within a minute, geometry and downstream level are unresolved. At the observed 14 cm head, the same assumed crest passes approximately 321 m³/h per metre. A ±2 cm change in crest reference changes the observed-bin estimate from roughly 124 to 297 m³ per metre. This sensitivity is larger than the precision suggested by a single volume number.[1][8]

Conditional overflow: change the assumptions

Illustrative free-weir rate and observed-bin volume only. Missing levels contribute no estimate and are reported as missing, not zero flow. C and b are unverified; submerged flow would need another relation and downstream measurements. [1,3,8]
Data & reproducibilitySELECT t,local,clean_level FROM minutes WHERE day IN ('2026-10-24','2026-10-25') ORDER BY t

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

A reverse-flow candidate with independent supporting signals

Physical candidate On 19 October 07:01–07:05 CEST, FT001 reports −73.9, −157.5, −141.0, −136.3 and −126.5 m³/h while both speeds indicate stopped pumps. The integrated indicated reverse volume is 10.59 m³. PT001 briefly reads −80 mbar and the level rises from −4.20 to −4.06 m NAP. The sequence follows a P100 run. On 20 October 04:24–04:27 CEST a smaller negative-flow sequence follows P200 operation.[1]

The concurrence of signed flow, pressure collapse and a rising well makes a hydraulic transient/reverse-flow explanation worth testing. A non-sealing or delayed check valve, an air-vessel transient or oscillatory flow near the transmitter are candidates. Sensor direction/scaling and timestamp alignment must also be checked. Minute averages cannot resolve water hammer; no check-valve failure is proven. Small negative offsets around −1.8 m³/h recur at many stops and must not be equated with the much larger 19 October event.[1][3][10]

19 October: signed flow, level, pressure and speed

The event is preserved by the proposed filter. The shared FT001 identifies station reverse flow; the preceding active pump identifies a candidate branch, not a confirmed leak path. [1]
Data & reproducibilitySELECT t,local,level_nap,flow,pressure,rpm100,rpm200 FROM minutes WHERE t BETWEEN '2026-10-19T04:50:00Z' AND '2026-10-19T05:20:00Z' ORDER BY t

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

Identical pumps, different branches: what separates the hypotheses?

P100 and P200 share FT001 and PT001. At low flow, stable matched bands (210–230 m³/h) give approximately 845 versus 857 rpm, 13.21 versus 14.09 kW indicated power, and almost the same header-to-well head: 14.31 versus 14.39 m. Mean model flow is 211.95 versus 221.74 m³/h against measured 220.08 versus 219.96 m³/h. Mean active motor current is approximately 65.88 versus 66.48 A: much closer than the indicated kW. Current alone does not establish input power or efficiency without voltage, power factor and register mapping. There are 663 and 632 flow pairs respectively; power and current use only their available subsets.[2]

A flowmeter error is possible, but not uniquely or most probably established. A shared calibration gain affects both pumps. Pump-dependent upstream swirl or velocity profiles could make the same meter respond differently to each branch, depending on its installation. Lower actual branch losses can also explain lower required speed and power at the same real flow. Differences in motor/drive calibration, efficiency, wear or impeller condition remain alternatives. These are identifiability limits, not equally supported diagnoses.[3][7][9][10]

The current model uses the same loss coefficient for both branches: 1.6451 × 10⁻⁵ m/(m³/h)². Its pump-axis height cancels out of the net static head; a 20 mm axis difference does not explain the bias. Under the joint assumption that the type curve, FT001, speed and PT001 are correct, the low-flow data imply median internal losses of about 0.44 m for P100 and 0.89 m for P200. At high P100 flow, implied loss is about 1.24 m against 2.65 m in the model. Branch-specific loss calibration is therefore a concrete competing explanation. It is not an independent measurement of pipe losses.[2][4]

Pump curve, SAT points and current operation on a common speed basis

Affinity normalization to 1,490 rpm makes the identical pump curves comparable. The full model head includes losses evaluated at predicted flow, creating mathematical dependence. Toggle to the measured header/well boundary to see the part without modelled internal losses. Neither is a direct differential-pressure measurement across the pump. SAT points are historical and have their own reference conventions. [2,3,4]
Data & reproducibilitySELECT t,pump,rpm,qMeas,head,head_external,required_loss FROM steady ORDER BY t

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

Model agreement is pump- and regime-dependent

All 3,757 stable flow pairs, not only the last 720 points returned for the original scatter plot. Negative residual means model below measurement. P100 has no contemporaneous P200 comparison above 350 m³/h. [2]
Data & reproducibilitySELECT t,pump,qMeas,qModel,pMeas,eModel FROM steady ORDER BY t

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

Inverse loss required for the same pump curve

For each observation, invert the curve using measured Q and speed, then subtract the PT001/LT001 boundary head. The common model K line is a hypothesis to compare. Negative implied losses expose inconsistency between assumptions; they are not negative friction. The inferred coefficients cannot by themselves identify the faulty instrument. [2,4]
Data & reproducibilitySELECT t,pump,qMeas,required_loss,required_k,loss FROM steady ORDER BY t

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

Explore residuals against possible explanatory signals

Within-pump and within-regime correlations are shown to reduce mixing of operating conditions. Serial correlation remains; the reported r is descriptive, with no causal p-value. Model head is partly computed from the same model being evaluated. A strong residual/head correlation is therefore not independent proof of a pressure defect. [2,4]
Data & reproducibilitySELECT t,pump,regime,bias,rpm,lv,pt,head,head_external,pMeas,CASE WHEN pump='P100' THEN i1 ELSE i2 END AS active_current FROM steady ORDER BY t

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

The historical SAT check is not a direct calibration target until head conventions are aligned. At low speed the type curve predicts roughly 226 versus 225 m³/h for P100. At its 1,300 rpm SAT point it predicts 493 versus 442 m³/h (+11.6%); other high-speed SAT differences are about +6–7%. In contrast, the current complete hydraulic model generally underpredicts P100. A global flow correction would obscure the distinction between pump curve, installation losses and metrology.[3]

Storage and inflow: test the inlet condition first

The inlet reference in the available ground truth is −3.80 m NAP. This is treated here as the documented inlet invert (BOB), not a verified pipe crown (BOP). Below an inlet invert, a freely discharging inlet does not provide directly communicating upstream storage at the wet-well level. Above the invert, partial-pipe storage/backwater may begin; the crown alone is not the onset of all network storage. Actual connectivity, invert and pressure conditions must be checked.[3][10]

Conditional calculation Of 136 complete cycles with a valid area estimate, 134 remain below −3.85 m NAP throughout the available 12-minute pre-run/run/post-stop level window. Their median effective area is 104.55 m² (middle half 96.48–109.48 m²). Missing level samples are not proof of the condition between observations; this is an available-sample screen. The discrepancy survives a 5 cm margin below the documented invert.[2]

The data do not establish five times more sewer storage. With 20.7 m² and the median observed slopes, inflow would be about 12 m³/h before pumping and 185 m³/h during pumping. Alternatively, assuming unchanged inflow and 20.7 m² would require real flow of only about 19.5% of FT001. This large inconsistency warrants checking the current wet-well geometry, level scaling/reference, actual inlet elevation/connectivity and correlated inlet variation. A shared flow bias of a few percent cannot explain a factor-of-five area mismatch.[2][3]

A=Qpsoff−sonQin=Qp+Adzdt
AEffective storage derivative dV/dzm²Inferred, constant over fitted window [2,4]
QₚPumped discharge; zero when truly stoppedm³/hFT001 [1,2]
s_off, s_onFitted level slopes before/during pumpingm/hLeast-squares fits in cycle algorithm [4]
QinInflow inferred by mass balancem³/hRequires known A and no other outflow
z,tLevel and elapsed timem, hLT001 and UTC timestamps
ConditionsEqual inflow for the area inversion; no overflow, reverse flow or unaccounted connected volume—Explicit assumptions, not measured facts

The large inferred area remains below the inlet

Area estimates for complete cycles, with the below-inlet screen highlighted. Lines at 20.7 and 16.46 m² are drawing/legacy-model values. The distribution is a conditional effective area, not a surveyed footprint. [2,3,4]
Data & reproducibilitySELECT id,start,pump,area,below_margin,max_level_window FROM cycles WHERE complete=1 AND area IS NOT NULL ORDER BY start

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

Inspect a complete cycle and its inlet clearance

Choose a cycle to see the available level and discharge around it. This makes the hydraulic prerequisite check auditable instead of hiding it behind an average area. [1,2]
Data & reproducibilitySELECT * FROM cycles WHERE complete=1 AND area IS NOT NULL ORDER BY start

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

What area would make before/during inflow agree?

Each pair uses the same cycle slopes. Agreement at ~105 m² is imposed by the inverse equation; it does not independently validate that area. The default 20.7 m² makes the inconsistency visible. [2,4]
Data & reproducibilitySELECT id,pump,riseOff,fallOn,flowMeas,area FROM cycles WHERE complete=1 AND below_margin=1 AND area IS NOT NULL

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

Reverse-engineering the sewer requires another independent constraint. During a pump-off, non-overflow period and with known storage, inflow can be inferred from the rise; it is still inferred, not directly measured. Above the inlet, the single equation contains two unknowns—Qin(t) and Aeff(z). The same level/flow trace cannot uniquely determine both. A useful next experiment is a bounded alternation of pump-on and pump-off periods with slowly varying inflow, surveyed wet-well geometry, upstream level and ideally an inlet flow reference. Then fit a piecewise storage curve, validate on held-out cycles, and propagate flow/level errors. Do not extrapolate the low-level 105 m² fit into the high-water/overflow range.[4][10]

Energy: running faster and starting more often are different costs

Two meanings of “opschakelen” need separate accounting. Increasing running speed changes head, flow and specific energy. Starting another pumping cycle adds a short ramp/transient and affects mechanical duty. Neither cost can be inferred solely from the number of starts.[2][10]

For P100 stable minutes with power available, low-flow operation averages 220.5 m³/h, 13.26 kW and 60.15 Wh/m³. High-flow operation averages 413.8 m³/h, 39.74 kW and 96.06 Wh/m³: about 36 Wh/m³ more (+59.7%), or an arithmetic 36 kWh per 1,000 m³ at those observed operating points. It is not an achievable saving: high flow occurs at much higher head (~25 versus 15 m) and may be needed to avoid flooding. The cubic speed law alone is not a site-energy estimate when static head and efficiency change.[2][10]

Measured operating-point energy, with sampling uncertainty

Wh/m³ is sum(indicated kW)/sum(measured m³/h) × 1,000 over exactly the same valid minutes. Error bars are a 1,000-resample contiguous-segment bootstrap; these segments may belong to the same long run, so this does not quantify systematic instrument uncertainty or independent-event confidence. P200 medium load has one segment; no interval is shown. [2]
Data & reproducibilitySELECT pump,regime,COUNT(*) AS n,1000*SUM(pMeas)/SUM(qMeas) AS wh_m3 FROM steady WHERE pMeas IS NOT NULL GROUP BY pump,regime

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

In 58 adjacent low-flow cross-pump cycle comparisons (within two hours, mean flow within 5 m³/h, model head within 0.3 m), P200 has a median +11 rpm, +0.12 m model head and +3.1 Wh/m³. These pairs can reuse a cycle; they are a descriptive cross-check, not 58 independent experiments. This comparison supports a persistent branch/pump measurement difference even after reducing operating-condition mixing.[2]

For 112 complete low-flow cycles with all required power minutes, the first two-minute energy minus a same-cycle steady Wh/m³ baseline has median 0.087 kWh, with the middle half 0.011–0.114 kWh. This is a transient-associated proxy, not isolated motor-start energy: the 30-second start at 50% command is blurred by minute averaging, pressure/storage change during the start, and the baseline assumes equal steady energy per unit volume.[2][3]

Transient-associated energy per start: a proxy with wide spread

All 112 qualifying runs. Negative values remain visible: the estimator is a counterfactual baseline, not a meter dedicated to starting losses. This proxy must not be used to book guaranteed savings. [2,4]
Data & reproducibilitySELECT start,pump,incremental_kwh,baseline_wh_m3,minutes FROM startup ORDER BY start

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

fstart=24AΔz(1Qin+1Qp−Qin)
fstartStation starts per 24 hoursday⁻¹Ideal constant-flow fill/drawdown cycle
AConstant effective aream²Scenario; not accepted geometry
ΔzStart minus stop levelmObserved 0.284; Cordis 0.3645; design 0.68 [2,3]
Qin, QpConstant inflow and pumping ratem³/hScenario, with 0 < Qin < Qp
24Hours in the hypothetical comparison dayh/dayTypical 24-hour scenario; not DST-day aggregation

At unchanged area and flows, a 0.284 m deadband implies about 2.39 times as many cycles as a 0.68 m band. Moving to 0.3645 m would reduce the ideal start count by about 22%; moving to 0.68 m by about 58%. These are geometric scenarios. Deeper drawdown also raises suction lift, can change air entrainment/NPSH and increases average pumping head; permitted levels and inlet conditions must be verified first. No PLC settings were changed.[2][3][10]

Deadband scenario: start count and transient proxy

The curve assumes constant A, constant Qin and 220 m³/h pumping, with no overflow or backflow. The right axis multiplies starts by the measured median 0.087 kWh transient proxy; it is an illustrative cost component, not total station energy. [2,3]
Data & reproducibilitySELECT start,pump,incremental_kwh FROM startup ORDER BY start

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

NRMSE, short-term error and the actual meaning of “long term”

The metric is NRMSE (normalized root mean squared error). It measures model disagreement, not a probability of failure. The deployed EVOLV pin is 9fcabe7f…; its generalFunctions and rotatingMachine submodule sources are embedded at their pinned commits, not assumed from a newer checkout.[4][5]

NRMSE=∑(ŷi−yi)2Nymax−yminLt=αNRMSEt+(1−α)Lt−1
ŷᵢ, yᵢPredicted and measured flow/powerSame unitsNative model measurement windows [5]
NPaired samples in short-term windowcountUp to 30 per pump and metric [5]
ymax − yminNormalization rangem³/h or kWCurrent model prediction surface range; fallback to available values [5]
LₜStored long-term NRMSD fielddimensionlessEWMA of nonnegative short-term NRMSE, not signed bias [5]
αEWMA gain—0.15; long-term readiness after 10 samples [5]
tUpdate indexcountModel assessments, not calendar days

“Long term” here does not mean 30 days. The short-term window is 30 samples; the EWMA has a half-life of about 4.27 updates, applied to already-windowed errors. Ten samples enable its mature output. Updates can be sparse or stop during pump-off periods, so neither is a fixed clock-time window. The exported seven-day history omits the normalization bounds, sample counts, reset events and the native long-term power series. Those missing fields prevent exact independent reconstruction of every native point.

Short-term default thresholds are 5%, 10%, 15%; long-term thresholds are 2%, 4%, 6%, using strict “greater than” comparisons. Thus a persistent 7% discrepancy can be “low” immediately and “high” long term without growing over time. Bias can also cancel while RMSE stays high, and changing the normalization range can change NRMSE even when error in m³/h is unchanged. Confidence values around 0.5 are internal scores, not a calibrated 50% probability that the pump is sound.[5]

Native model errors as actually exported

Solid = native rolling flow NRMSE; dashed = native flow EWMA; dotted = native power NRMSE. Gaps remain gaps. Threshold lines refer to long-term flow, not to short-term power. Stored values were sampled from an event-driven runtime; the history is not the complete state trajectory. [2,5]
Data & reproducibilitySELECT t,mp,r1,r2,efn,native_flow_ewma,native_flow_level,epn,econf FROM history WHERE efn IS NOT NULL ORDER BY t

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

Native values on stable operating rows with native output available. This is descriptive row occupancy, not independent assessments, failure frequency or duration. Low ≤240; medium 240–350; high >350 m³/h. No P200 high-flow comparison is available. [2,5]
PumpFlow regimeAvailable stable rowsMedian flow NRMSEMedian flow EWMAMedian power NRMSERows with flow EWMA >6%Native bias (m³/h)Shadow bias, same rows (m³/h)
P100low3016.50%6.40%7.10%66.4%-7.94-8.01
P100medium1413.70%3.80%11.00%17.0%-19.45-19.91
P100high4044.20%4.20%11.85%3.0%-24.78-25.79
P200low2697.30%7.30%6.60%75.8%+1.97+2.01
P200medium641.20%2.30%5.75%23.4%-5.65-6.11

A useful inconsistency: P200 at low flow has only about +1.97 m³/h mean instantaneous native flow bias on these rows, yet its median native flow NRMSE is 7.3%. P100 low flow has −7.94 m³/h bias and 6.5% median native NRMSE; at high flow its bias grows to −24.78 m³/h while median native NRMSE drops to 4.2%. Thus the native percentage is not simply the current error divided by current flow. The dynamic normalization range, rolling window, transients and update history can all influence the ranking. Missing per-point normalization bounds prevent attribution among them. Do not rank pump condition directly by these percentages. On the same available rows, instantaneous native and shadow mean biases are close; their windowed diagnostics still answer different questions.[2][5]

Native percentage versus instantaneous signed flow error

Each point links the recorded native flow NRMSE to the same row’s native predicted flow minus FT001. The y value summarizes an earlier window and uses a dynamic denominator; the x value is instantaneous. This is a consistency diagnostic, not an equation that should lie on a single line. Filter by pump and regime to inspect the effect. [2,5]
Data & reproducibilitySELECT t,pump,regime,evq-qMeas AS native_signed_error,efn,native_flow_ewma,bias AS shadow_signed_error FROM steady WHERE evq IS NOT NULL AND efn IS NOT NULL ORDER BY t

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

A transparent additional diagnostic: fixed-scale error and signed bias

This is recomputed from the 3,757 stable shadow-model pairs, not a replay of native EVOLV. Rolling 30 accepted observations per pump, minimum 5; fixed normalization of 424 m³/h; alpha 0.15 EWMA after 10 available rolling estimates. Signed bias preserves direction. Windows can span pump-off intervals. [2,4]
Data & reproducibilitySELECT t,pump,rmse30_fixed_pct,ewma_fixed_pct,bias30_pct FROM steady ORDER BY t

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

For maintenance monitoring: retain raw error in engineering units, signed bias, explicit normalization bounds, sample count, operating regime, quality flags and model/configuration version. Compare each pump against its own validated branch baseline, then compare their residual changes under matched conditions. A persistent offset is a calibration question; a change within the same validated regime is a stronger deterioration signal. Both still need independent inspection.

Long-term trend and the Emotron distinction

The long-term chart ends on 19 October 2026; its “last 30 days” are not the same window as the current week. It contains 988 calendar rows from 2024, but valid energy increments start on 9 April 2025. The “energy since start” sum therefore must not be described as complete energy since renovation. The latest 60-day lower envelope is about 14.44 kW for P100 and 15.01 kW for P200. Within 2026 this does not establish a monotonic degradation trend; operating mix, resets and availability still matter.[6]

The historian provides daily means of cumulative counters, then the application differences those means. These are not exact midnight-to-midnight meter deltas; fractional start counts expose the averaging. Quality metadata record 13/12 energy resets and 50/44 hours-counter resets for P100/P200, plus rejected steps. Filtered sums and ratios should use the intersection of valid energy and runtime days. No valid range can repair an incorrectly defined source counter.[6][4]

Long-term power-per-running-hour and its lower envelope

Thin traces: 14-row sums of energy divided by runtime on jointly available days. Thick traces: the application’s 10th-percentile 60-row envelope on days with ≥1 running hour. This is an operating-condition proxy, not a weather-classified or head-normalized efficiency index. [6]
Data & reproducibilitySELECT day,kw14_100,kw14_200,floor100,floor200 FROM longterm ORDER BY day

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

What “Emotron” means here: it is the variable-frequency drive. An official FDU-family manual distinguishes a shaft-power output [714] from an electrical output-power signal [715]; it also has an energy counter [733]. That establishes that several different quantities exist. It does not establish which register the Klundert PLC exports as Meting.Vermogen, nor that this older reference manual matches the installed firmware. The tag mapping and drive parameter number are still required.[11]

If the tag is shaft power, compare with model shaft power. If it is electrical power delivered by the drive to the motor, include motor losses but not drive input losses. If it is grid input power, include both. The current comparison includes motor losses and an assumed 97% drive efficiency. Its −8% bias cannot be interpreted as actual energy loss until these measurement boundaries agree. The site tag is therefore called indicated power throughout this artifact; cycle integrals inherit that uncertainty.[3][4][11]

Automatic filtering, provenance and the winter-time day

Implemented in this artifact Raw records remain intact in SQLite. A separate flag excludes the six records where LT001 = 0 m NAP and flow, pressure and both speeds simultaneously equal zero. This is a station-specific coherence rule supported by rapid return to normal surrounding levels, not a generic “delete zeros” rule. Negative flow, pump-off zero flow, flat setpoints and real high levels are retained. Each graph’s SQL and exclusions remain inspectable.[1]

Other rules should mark suspect data rather than silently replace it: source bad-quality codes; impossible physical ranges after unit conversion; time misalignment; duplicate event times; counters going backwards; implausible isolated jumps; and saturation/stuck values only when corroborated by other channels. The acquired chart API does not expose all original historian quality codes, so this artifact cannot retrospectively apply those tests. Interpolation is never treated as observation. Derived model/drift/energy results need their own validity masks.

Automatic coherence filtering preserves the raw evidence

The 20 October 10:11 CEST spike is retained as a flagged raw point and removed only from the analytical series. A momentary raw 0 m NAP becomes 5.05 m above the floor after unit conversion; the filter explicitly knows that mapping. [1,3]
Data & reproducibilitySELECT t,local,level_nap,clean_level,flow,pressure,zero_invalid FROM minutes WHERE t BETWEEN '2026-10-20T08:05:00Z' AND '2026-10-20T08:18:00Z' ORDER BY t

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

Coverage and the 25-hour day

Day lengths are computed between local midnight boundaries in UTC. Partial first/last days are labelled as window coverage, not full days. Missing flow on 25 October is 128 minutes in the fixed window; missing levels are larger. The absence cannot be repaired by dividing all days by 1,440. [1]
Data & reproducibilitySELECT day,expected_minutes,window_minutes,flow_minutes,level_minutes,missing_flow FROM daily ORDER BY day

Query the embedded SQLite database below; raw source responses and exact model code are included. No live query is used to draw this figure.

Confirmed timestamp mechanism: the historian adapter rejects offset-free local timestamps that map to two Amsterdam instants. On 25 October, local 02:00–02:59 occurs twice (UTC 00:00–00:59 and 01:00–01:59). A response containing only a wall-clock label cannot identify the occurrence. The raw API reports a gap spanning this region. That code behaviour explains a credible mechanism; the missing source payload itself was not available to prove the provenance of each absent minute.[4]

Correct resolution: keep UTC event coordinates, show the local offset on hover, identify the repeated-hour interval, count 1,500 minutes for the day, and require an explicit UTC/offset or trustworthy occurrence/order metadata from the source. Historical values can only be restored by re-reading an unambiguous source and performing a versioned backfill. Fabricating duplicate values or choosing one offset would create false evidence. The artifact implements the UTC representation, day-length calculation and missing-data annotation; historical recovery remains open.

Application follow-up: code-level corrections and rollout evidence are listed in the delivery record below. Artifact filtering is active independently of the live application.

Cause matrix and a discriminating field plan

The following matrix separates observations from mechanisms. No failure probability is assigned. P100/P200 identity and short separation remove some design variability but do not make branch loss, sensor response, wear state or motor setup identical. Physics mechanisms below are hypotheses to test, supported by the energy and hydraulic relationships and manufacturer measurement guidance.[7][9][10][11]

Evidence-ranked investigation matrix. “Possible” means compatible with incomplete data, not detected. [1–11]
CandidateEvidence statusWhy it is in scopeTest that distinguishes it
Different pipe-branch lossesHigh-priority competing hypothesisSame K is used for both branches; P200 needs more speed at similar FT001/header conditions.Pump-flange suction/discharge pressure plus matched-flow runs; survey fittings/valve openings.
FT001 gain or branch-dependent profilePlausible; not ranked above branch lossesShared transmitter: common gain alone cannot explain pump-specific offset; changed inflow profile can.Independent portable/reference meter, installation audit, direction and zero check.
PT001 offset / height / dynamic responsePlausibleShared sensor; head and curve residual are strongly coupled; local sensor elevation is assumed.Calibrate pressure, survey tapping elevation, synchronized flange reference.
LT001 scaling / zero / geometryHigh priority for water balance105 m² inversion persists below the documented inlet; six cross-channel zero bursts.Independent level reference at several heights, 4–20 mA/PLC scaling and wet-well survey.
Check-valve leakage / closing transientEvent-specific candidate19 October negative flow, pressure dip and rising level after P100 stops.Valve inspection and high-rate synchronized signed flow/pressure around stops.
Impeller wear, ragging, clearance, rotationPossible, no diagnosisIdentical nominal pumps can differ in condition; no matched baseline or inspection exists.Inspection, impeller identity/trim, vibration and repeatable Q–H–P acceptance test.
Air entrainment / cavitation / suction restrictionPossible, unmeasuredLow suction submergence may matter; minute data cannot resolve pressure pulsation or NPSH margin.Suction absolute pressure, liquid temperature, NPSHr curve, vibration/acoustics, vortex observation.
Motor heating / cooling / bearingsUnmeasured thermal hypothesisLong P100 duty differs from short cycles; no winding, bearing or ambient temperature was acquired.Temperature and vibration trend at matched hydraulic load; motor/drive thermal model audit.
Drive register / motor parameter mismatchPriority metrology checkAs-power and electrical-output registers exist; the site tag mapping is unverified.Read parameter/register mapping, rated motor data, identification run and independent power meter.
Density / viscosity / solids / foulingPossible but unconstrainedWater properties are assumed (998.2 kg/m³); no temperature/solids series is present.Liquid temperature and solids; verify curve applicability and clean-water baseline.
Timestamp, quality, aggregation / counter resetsObserved data limitationsRepeated hour, zero bursts, sparse native output and different collectors produce different totals.UTC provenance, quality flags, aligned windows, audited backfill and counter-reset events.
Model structure / dynamic normalizationObserved modelling limitationCommon branch K, uncertain power boundary and changing NRMSE range.Versioned branch model, explicit measurement boundary, logged NRMSE denominator and residual baseline.

Thermal limits: higher winding temperature increases copper resistance and losses; bearing friction and reduced low-speed cooling can change indicated power. Those mechanisms cannot be separated here because no temperature or loss measurements were collected. Motor current alone is not electrical power: voltage, phase/power factor, waveform and measurement boundary matter with a drive. Inferring temperature or motor efficiency from the 66 A signals would exceed the evidence. A higher observed power can also be the correct hydraulic response to higher head. The pinned rotatingMachine boot code seeds a 15 °C temperature value; this is a software default, not an acquired Klundert temperature measurement. It must not be presented as thermal evidence.[5]

Recommended order: (1) confirm crest/inlet elevations and inspect the reverse-flow event; (2) independently verify FT001, LT001, PT001 and drive power mapping; (3) alternate pumps at matched flow/level/header pressure and identify per-branch loss; (4) survey storage and fit an above-inlet network model using upstream level/inflow constraints; (5) establish a stable, versioned residual baseline before using drift for maintenance alarms. No operating setting, calibration or physical control has been changed by this analysis.

The presentation value is not “we diagnosed the pump from a month of data”. It is that a small dataset can locate concrete inconsistencies, distinguish measurable facts from assumptions, quantify conditional effects, and specify the next measurement that will resolve each competing explanation.

Open the evidence: SQLite, SQL, source rows and calculation code

The database and SQL engine are embedded in this HTML. After loading the artifact, figures query the browser-local database; no EVOLV API is called. The SQL explorer displays up to 200 rows; CSV exports the full query result. To reproduce the calculations, save the SQLite and reproduce.py together, then run python3 reproduce.py klundert-20261030.sqlite with Node.js and Python NumPy/pandas/SciPy installed. The helper verifies hashes, extracts source and pinned code into a new directory, regenerates the stable pairs and reruns the analysis. Raw API responses, their hashes and source URLs are in sources; calculation and pinned model code are in code.

Source/schema inventory and known omissions

The fixed history export lacks the native power EWMA, per-point normalization bounds, update counts and complete runtime reset trajectory. Empty fields remain empty. Raw source JSON is preserved alongside the normalized tables. Units: FROST level is metres above floor; level_nap = level − 5.05. History lv is already m NAP. pressure is mbar; power is indicated kW; Q is m³/h.

Sources and provenance

  1. Frozen FROST minute series. EVOLV API /evolv/api/series, site=klundert; seven channels; thirty one-day requests, points=2000. Full exact URLs, JSON bodies and SHA-256 hashes in SQLite sources. Retrieved 30 October 2026. Source ↗
  2. Frozen twin views. history?hours=168, analysis?hours=168 and trends from /evolv/api/klundert. Snapshot around 30 October 2026 11:38 UTC. Stable-pair filter reproduced exactly (3,757 pairs); original scatter API retained only 720 recent points. Source ↗
  3. Klundert maatgeving. Full current maatgeving.json and derived curves/SAT points. References include D1 ZRG00033-09-002, D2 ZRG00033-22-002, D6 ZRG00033-12-004, D20, D21, D27 and D31. These facts were read from the source-labelled API snapshot; original catalogue PDFs require authentication and were not independently re-read for this report. Source ↗
  4. EVOLV waterketen analytical code. Repository main 37fa61b as inspected; runtime-klundert/analysis.cjs, hydraulics.cjs, views.cjs, server/zinfo.mjs and zinfo-client.mjs. Calculation code stored in SQLite and downloadable. Source ↗
  5. Pinned native drift implementation. EVOLV 9fcabe7f444a923bdc1504fc5383e37558aeabad; generalFunctions f59e78272abd363df869af90600c6c24f36c2dec; rotatingMachine ebd0753ba6c5e32b2429cc90574a52e1ecd92a22. Exact errorMetrics, nrmseConfig, rotatingMachine and driftAssessor source included, with hashes. Source ↗
  6. Long-term historian snapshot. Z-info daily means of pump counters, converted to day steps; generated 19 October 2026 05:20 UTC. 988 day rows; energy valid from 9 April 2025; quality counts preserved. Source ↗
  7. Owner clarification. User message, 30 October 2026: P100 and P200 are the same pump; only pipework differs; approximately two metres apart. This is owner-supplied evidence.
  8. US Bureau of Reclamation. Water Measurement Manual, chapter 2 §9 (thin-plate relation) and chapter 7 §3 (free/submerged conditions); accessed 30 October 2026. Coefficients in this artifact are explicit illustrative SI assumptions. Source ↗
  9. Endress+Hauser. The Maintenance Guide, electromagnetic flowmeter installation: upstream disturbances and installation-dependent measurement error. General manufacturer guidance; the actual FT001 make/installation was not verified. Accessed 30 October 2026. Source ↗
  10. US DOE / Hydraulic Institute. Improving Pumping System Performance, second edition, 2006: hydraulic system boundaries, operating point, variable speed and maintenance. Used for general physical mechanisms, not as proof of a Klundert fault. Accessed 30 October 2026. Source ↗
  11. Emotron manufacturer manual. FDU 2.0-2Y, 01-5665-01r0, software 4.36. PDF p.171 distinguishes [714] shaft power and [715] electrical output power; p.177 describes [733] energy. Reference family/version, not confirmed installed drive firmware. Accessed 30 October 2026. Source ↗
Data vintage Fixed 30-day minute window ending 2026-10-30 11:35 UTC; native model history seven days; long-term counters end 2026-10-19.
Method Quality-preserving SQL queries; exact steady-pair reproduction; conditional hydraulic inversion; explicit scenario bounds; descriptive correlations.
Tooling Python/pandas/NumPy/SciPy · SQLite · embedded sql.js 1.13.0 (MIT) · self-hosted Plotly / HELIX theme.
Database SHA-256ebd8b452359b0d3e206629de6d59b1f9e17bf20e0be9802bf4d6929d98e9eb10
Delivery recordArtifact v1.1: 21 interactive figures, verified SQLite and exact regeneration of all nine derived tables. EVOLV PR #169 merged as 310b81e3 (v0.3.20). Required checks passed; automated image deployment succeeded 30 October 2026 12:57 UTC, and static publication succeeded. Live browser checks confirmed a 25-hour UTC interval, distinct local offsets, the winter-time notice, rejection of ambiguous calendar boundaries and zero-record exclusion. Live API checks confirmed the 19 October reverse-flow values remain visible. Local application suite: 537 passed, 46 skipped, zero failures. Historical DST recovery remains open; no missing values have been invented.
Contact WBD R&D · Predictive Maintenance