  "revision": "0.3.103",
  "sourceDrawing": {
    "file": "bouwkundig_p1.png",
    "sha256": "313d5fb143b160196c846ac3f41eb8ef82254274b5b3472fc8e117fa590e09c8",
    "identifier": "ZRG00033-02-001 REV:1 STATUS:As built; title block ZRG00033-02-002",
    "date": "2024-04-04",
    "views": [
      "Plattegrond Begane grond",
      "Plattegrond Kelder",
      "Doorsnede D-D",
      "Doorsnede E-E"
    ],
    "publicCrops": [
      "klundert-plan-upper.png",
      "klundert-section-dd.png"
    ]
  },
  "photoCheck": {
    "file": "klundert-photo-entry-overview.jpg",
    "original": "DJI_20261112123430_0104_D.JPG",
    "observations": [
      "Facing the three round windows: stairwell left, double entry door on right-hand perpendicular wall.",
      "Cabinets and drives on the side opposite the windows."
    ]
  },
  "dimensioned": {
    "upperClearCrossWidthM": 5.59,
    "upperCrossWidthChainMm": [
      2023,
      150,
      3417
    ],
    "upperClearLengthM": 6.805,
    "upperLengthChainMm": [
      1880,
      100,
      1200,
      2200,
      1425
    ],
    "windowCentreChainMm": [
      1525,
      1870,
      1870,
      1540
    ],
    "doorClearWidthM": 2.4,
    "roundWindowDiameterM": 1.0,
    "upperFloorNapM": -0.455
  },
  "registration": {
    "method": "Align window-side wall to retained wet-side cellar wall (Z=.729); extend upper footprint 2.171 m towards cabinet side. Long-axis offsets approximately .24 and .265 m scaled from the dashed cellar outline on the upper plan. Retained cellar is already approximate.",
    "upperBounds": {
      "minX": -2.415,
      "maxX": 4.39,
      "minZ": -4.861,
      "maxZ": 0.729
    },
    "retainedCellarBounds": {
      "minX": -2.15,
      "maxX": 4.15,
      "minZ": -2.69,
      "maxZ": 0.729
    },
    "stairwellScaled": {
      "minX": 2,
      "maxX": 4.15,
      "minZ": -2.69,
      "maxZ": -0.45
    },
    "note": "The upper slab opening covers both flights. Upper stair run shortened to 1.2 m to meet its plan-scaled entrance; tread runs/landing positions are approximate, not explicit drawing dimensions."
  },
  "limits": [
    "Drawing says dimensions require field verification.",
    "Existing installation is recognisable, not CAD-precise; its coordinates and bytes are retained.",
    "Dry cellar retained clear width 3.419 m differs 2 mm from the upper dimension chain value 3.417 m. No precision claim.",
    "Ceiling, cabinet depths, small fittings and photo-comparison camera pose are approximate.",
    "COLMAP sparse reconstruction has not been registered to this model and did not determine this correction."
  ]
}