# valve > **Reflects code as of `e27135b` · regenerated `2026-05-11` via `npm run wiki:all`** > If this banner is stale, the page may be out of date. Treat as informative, not authoritative. ## 1. What this node is **valve** models a single actuated throttling valve at the S88 Equipment Module level. It loads a supplier Kv-vs-position characteristic curve, drives an FSM for open/close move sequences (using `accelerating`/`decelerating` states shared with `rotatingMachine`), and recomputes pressure drop from flow + Kv via a hydraulic model. Used standalone or as a child of `valveGroupControl`. ## 2. Position in the platform ```mermaid flowchart LR vgc[valveGroupControl
Unit]:::unit -->|set.position| this[valve
Equipment]:::equip src["machine / MGC / PS
(upstream source)"]:::unit -->|child.register| this meas[measurement
type=pressure / flow]:::ctrl -.->|data| this this -->|child.register Port 2| vgc this -->|evt.deltaPChange| vgc this -->|evt.fluidCompatibilityChange| vgc classDef unit fill:#50a8d9,color:#000 classDef equip fill:#86bbdd,color:#000 classDef ctrl fill:#a9daee,color:#000 ``` S88 colours: Unit `#50a8d9`, Equipment `#86bbdd`, Control Module `#a9daee`. Source: `.claude/rules/node-red-flow-layout.md`. ## 3. Capability matrix | Capability | Status | Notes | |---|---|---| | Predicts deltaP from flow + Kv | ✅ | Hydraulic model picks liquid vs gas formula per `serviceType`. | | Loads supplier curve by model name | ✅ | `asset.model` resolved through `loadModel`; inline `valveCurve` override supported. | | Position move FSM | ✅ | `accelerating` / `decelerating` states with interruptible setpoints; `moveTo` uses shared state machine. | | Startup / shutdown sequences | ✅ | Pre-shutdown ramps valve to position 0 before executing stop sequence. | | Emergency-stop sequence | ✅ | `cmd.estop` → `emergencystop → off` sequence. | | Fluid-contract aggregation | ✅ | Tracks upstream service type via registered sources through `FluidCompatibility`. | | Gas-choke detection | ⚠️ | Hard cap at `gasChokedRatioLimit`; surfaced in `hydraulicDiagnostics`. | | Multi-parent registration | ⚠️ | Allowed but not exercised in production tests. | ## 4. Code map ```mermaid flowchart TB subgraph nodeRED["nodeClass.js — adapter (BaseNodeAdapter)"] nc["buildDomainConfig()
static DomainClass=Valve, commands
tickInterval=null (event-driven)"] end subgraph domain["specificClass.js — orchestrator (BaseDomain)"] sc["Valve.configure()
wires concern modules
overrides registerChild → FluidCompatibility"] end subgraph concerns["src/ concern modules"] state["state/
stateBindings → positionChange"] fluid["fluid/
FluidCompatibility"] curve["curve/
SupplierCurvePredictor"] meas["measurement/
MeasurementRouter + FORMULA_UNITS"] flow["flow/
FlowController (setpoint, sequences)"] io["io/
buildOutput + buildStatusBadge"] hyd["hydraulicModel.js
ValveHydraulicModel"] end nc --> sc sc --> state sc --> fluid sc --> curve sc --> meas sc --> flow sc --> io sc --> hyd ``` | Module | Owns | Read first if you're changing… | |---|---|---| | `state/` | Bindings from state-machine `positionChange` → `updatePosition()` | Move-finished triggers, position callbacks. | | `fluid/` | Service-type compatibility, contract aggregation | Gas-vs-liquid mismatch warnings, upstream fluid tracking. | | `curve/` | Supplier Kv curve load + interpolation | Curve fitting, model selection, density keys. | | `measurement/` | Pressure/flow routing + deltaP recompute | What triggers a recalc, measurement container writes. | | `flow/` | Sequence + setpoint execution, mode validation | Startup / shutdown / move semantics, allowed-source checks. | | `io/` | Port-0 output shape + status badge | What lands on the wire each tick. | | `hydraulicModel.js` | Liquid + gas deltaP formulas, choke detection | Hydraulic calculation errors, choke ratio behaviour. | ## 5. Topic contract > **Auto-generated** from `src/commands/index.js`. Do NOT hand-edit between the markers. Re-run `npm run wiki:contract`. | Canonical topic | Aliases | Payload | Unit | Effect | |---|---|---|---|---| | `set.mode` | `setMode` | `string` | — | Switch the valve between auto / manual control modes. | | `cmd.startup` | _(none)_ | `any` | — | Initiate the valve startup sequence. | | `cmd.shutdown` | _(none)_ | `any` | — | Initiate the valve shutdown sequence. | | `cmd.estop` | `emergencystop`, `emergencyStop` | `any` | — | Trigger an emergency stop on the valve. | | `execSequence` | _(none)_ | `object` | — | Legacy umbrella that demuxes payload.action to startup / shutdown / estop. | | `set.position` | `execMovement` | `object` | — | Move the valve to a control-% position via execMovement. | | `data.flow` | `updateFlow` | `object` | — | Push a measured flow into the valve (variant + position + unit). | | `query.curve` | `showcurve` | `any` | — | Return the valve characteristic curve on the reply port. | | `child.register` | `registerChild` | `string` | — | Register a child measurement with this valve. | ## 6. Child registration valve overrides `BaseDomain.registerChild` with `FluidCompatibility.registerChild`. Upstream sources feed the fluid-contract aggregator; measurement children attach through the standard measurement handshake and land in `MeasurementRouter`. ```mermaid flowchart LR subgraph kids["accepted children (softwareType)"] src["machine / rotatingmachine
machinegroup / pumpingstation
valvegroupcontrol"]:::unit m["measurement
type=pressure or flow"]:::ctrl end src -->|getFluidContract| fluid[FluidCompatibility
aggregates serviceType] m -->|"<type>.measured.<position>"| router[MeasurementRouter
updatePressure / updateFlow] router --> deltaP[updateDeltaP
writes pressure.predicted.delta] fluid --> evt1["evt.fluidCompatibilityChange
evt.fluidContractChange"] deltaP --> evt2[evt.deltaPChange] classDef unit fill:#50a8d9,color:#000 classDef ctrl fill:#a9daee,color:#000 ``` | softwareType | onRegister side-effect | Subscribed events | |---|---|---| | `machine` / `rotatingmachine` | Stored as upstream source; reads `getFluidContract()` or defaults to `liquid`. | `fluidContractChange` | | `machinegroup` / `machinegroupcontrol` | Same; recomputes aggregate service type. | `fluidContractChange` | | `pumpingstation` | Same. | `fluidContractChange` | | `valvegroupcontrol` | Same. | `fluidContractChange` | | `measurement` | Routed via measurement handshake; values land in `MeasurementContainer`. | `.measured.` | ## 7. Lifecycle — what one event does ```mermaid sequenceDiagram participant parent as valveGroupControl participant valve as valve participant fsm as state FSM participant hyd as hydraulicModel participant out as Port-0 parent->>valve: set.position { setpoint: 60 } valve->>fsm: moveTo(60) fsm-->>fsm: operational → accelerating fsm-->>valve: positionChange ticks (stateBindings) valve->>valve: predictKv(position) valve->>hyd: calculateDeltaPMbar(q, kv, downP, rho, T) hyd-->>valve: { deltaPMbar, diagnostics } valve->>valve: write pressure.predicted.delta valve->>parent: emitter.emit('deltaPChange', deltaP) valve->>out: msg { topic, payload (delta-compressed) } fsm-->>fsm: accelerating → operational (setpoint reached) ``` ## 8. Data model — `getOutput()` What lands on Port 0. Composed in `io/output.buildOutput`, then delta-compressed by `outputUtils.formatMsg`. | Key | Type | Unit | Sample | |---|---|---|---| | `state` | string | — | `"operational"` | | `percentageOpen` | number | % | `0` | | `moveTimeleft` | number | s | `0` | | `mode` | string | — | `"auto"` | | `downstream_predicted_flow` | number | m3/h | `0` | | `downstream_measured_flow` | number | m3/h | _(emitted when measurement child present)_ | | `downstream_predicted_pressure` | number | mbar | _(emitted when upstream pressure present)_ | | `downstream_measured_pressure` | number | mbar | _(emitted when measurement child present)_ | | `delta_predicted_pressure` | number | mbar | `0` | Measurement keys follow the legacy `__` shape (e.g. `downstream_predicted_flow`, `delta_predicted_pressure`). Only keys with finite values are emitted — consumers must cache and merge (delta-compression is active). ## 9. Configuration — editor form ↔ config keys ```mermaid flowchart TB subgraph editor["Node-RED editor form"] f1[Reaction Speed] f2[Asset model / supplier / category] f3[Service type] f4[Fluid density / temperature K] f5[Gas choke ratio limit] f6[Startup / warmup / shutdown / cooldown times] f7[Log level / enableLog] f8[positionVsParent] end subgraph config["Domain config slice"] c1["movement.speed (stateConfig)"] c2[asset.model] c3["runtimeOptions.serviceType → hydraulicModel"] c4["runtimeOptions.fluidDensity / fluidTemperatureK"] c5["runtimeOptions.gasChokedRatioLimit"] c6["stateConfig.time.starting / warmingup / stopping / coolingdown"] c7["general.logging.enabled / logLevel"] c8["functionality.positionVsParent → Port-2 registration"] end f1 --> c1 f2 --> c2 f3 --> c3 f4 --> c4 f5 --> c5 f6 --> c6 f7 --> c7 f8 --> c8 ``` | Form field | Config path | Default | Range / type | Where used | |---|---|---|---|---| | Reaction Speed | `movement.speed` (stateConfig) | `1` | > 0 (%/s) | `MovementManager` — sets rate of position change | | Asset model | `asset.model` | `'Unknown'` | string | `SupplierCurvePredictor` — selects Kv curve dataset | | Service type | `runtimeOptions.serviceType` | `null` (from asset) | `'gas'` / `'liquid'` | `ValveHydraulicModel` formula selection | | Fluid density | `runtimeOptions.fluidDensity` | model default | > 0 (kg/m³) | liquid hydraulic formula | | Fluid temperature | `runtimeOptions.fluidTemperatureK` | model default | > 0 (K) | gas hydraulic formula | | Gas choke limit | `runtimeOptions.gasChokedRatioLimit` | per asset | 0–1 | gas choke cap in `ValveHydraulicModel` | | Startup time | `stateConfig.time.starting` | `10` s | > 0 (s) | `StateManager` transition timer | | Warmup time | `stateConfig.time.warmingup` | `5` s | > 0 (s) | `StateManager` protected transition | | Shutdown time | `stateConfig.time.stopping` | `5` s | > 0 (s) | `StateManager` transition timer | | Cooldown time | `stateConfig.time.coolingdown` | `10` s | > 0 (s) | `StateManager` transition timer | | Mode | `mode.current` | `'auto'` | `auto` / `virtualControl` / `fysicalControl` / `maintenance` | `FlowController.isValidSourceForMode` | | Log level | `general.logging.logLevel` | `'info'` | enum | structured logger | | positionVsParent | `functionality.positionVsParent` | `'atEquipment'` | enum | Port-2 registration message to parent | ## 10. State chart ```mermaid stateDiagram-v2 [*] --> off off --> idle : cmd.startup (boot sequence) off --> emergencystop : cmd.estop off --> maintenance : set.mode=maintenance idle --> starting : cmd.startup idle --> off : (direct transition) idle --> emergencystop : cmd.estop idle --> maintenance : set.mode=maintenance starting --> warmingup : timed (starting duration) starting --> emergencystop : cmd.estop warmingup --> operational : timed (warmup duration) [protected — cannot abort] warmingup --> emergencystop : cmd.estop operational --> accelerating : set.position > current operational --> decelerating : set.position < current operational --> stopping : cmd.shutdown operational --> emergencystop : cmd.estop accelerating --> operational : setpoint reached accelerating --> emergencystop : cmd.estop decelerating --> operational : setpoint reached decelerating --> emergencystop : cmd.estop stopping --> coolingdown : timed (stopping duration) stopping --> idle : (direct) stopping --> emergencystop : cmd.estop coolingdown --> idle : timed (cooldown duration) [protected — cannot abort] coolingdown --> off : (direct) coolingdown --> emergencystop : cmd.estop emergencystop --> idle : cmd.reset / sequence emergencystop --> off : cmd.reset / sequence emergencystop --> maintenance : (allowed) maintenance --> idle : manual reset maintenance --> off : manual reset ``` **Key valve-specific behaviours:** - `accelerating` = position moving up; `decelerating` = position moving down. Both fire `positionChange` ticks. The valve's `stateBindings` hooks these to `updatePosition()` → Kv lookup → deltaP recompute. - `warmingup` and `coolingdown` are **protected** — the abort signal is disabled; these phases cannot be interrupted. - `cmd.shutdown` from `operational` first ramps the valve to position 0 (via `FlowController.executeSequence('shutdown')`), then transitions `stopping → coolingdown → idle`. - `cmd.estop` triggers `emergencystop → off` regardless of current state (except from within protected transitions). - Default sequences: `startup` = `[starting, warmingup, operational]`; `boot` = `[idle, starting, warmingup, operational]`; `emergencystop` = `[emergencystop, off]`. ## 11. Examples | Tier | File | What it shows | Mandatory? | |---|---|---|---| | Basic | `examples/basic.flow.json` | Inject `set.position` + minimal wiring, no parent | ✅ | | Integration | `examples/integration.flow.json` | valve + VGC + upstream measurement source | ✅ | | Edge | `examples/edge.flow.json` | Edge-case inputs (gas, choke, estop, bad setpoints) | ⭕ optional | Renamed example files (`01-Basic.flow.json`, `02-Integration.flow.json`, `03-Dashboard.flow.json`) will replace the above when produced. Screenshots under `wiki/_partial-screenshots/valve/`. Docker compose snippet under `examples/README.md`. ## 12. Debug recipes | Symptom | First thing to check | Where to look | |---|---|---| | Status badge shows `⚠ no input` | Did any pressure / flow measurement register? Watch Port 2. | Debug tap on Port 2 | | `delta_predicted_pressure` stuck at `0` | Is `kv > 0`? FSM may be in `off` / `idle` — valve is closed. | `state.getCurrentState()`, `percentageOpen` | | Gas mismatch warning on status badge | `fluidCompatibility.status` is `mismatch` or `conflict`. | `getFluidCompatibility()` | | `query.curve` returns empty curve | `asset.model` not found by `loadModel`; check `SupplierCurvePredictor.snapshot()`. | `SupplierCurvePredictor.snapshot()` | | deltaP non-finite | Downstream gauge pressure absolute term ≤ 0, or choked ratio reached. | `hydraulicDiagnostics` in output | | `set.position` has no effect | Check `currentMode` — source may not be in `mode.allowedSources[mode]`. | `FlowController.isValidSourceForMode` | | FSM stuck in `accelerating` / `decelerating` | Movement was aborted but `_returnToOperationalOnAbort` was false. Send a new `set.position`. | `state.js` abort logic | > Never ship `enableLog: 'debug'` in a demo — fills the container log within seconds and obscures real errors. Use only for live debugging. ## 13. When you would NOT use this node - Use valve for a **throttling actuator** with a known Kv curve. For a fixed-restriction orifice (no actuator, no curve), model the deltaP externally. - Don't use valve to model a **non-return / check valve** — no position control or FSM-driven actuation is exposed. - Skip valve when an upstream source already provides flow directly and **no pressure-drop estimate is needed** — wire the source straight to the parent without inserting a valve. ## 14. Known limitations / current issues | # | Issue | Tracked in | |---|---|---| | 1 | Gas-choke detection is a hard cap, not a smooth transition — chart traces show a step at the choked-ratio limit. | `hydraulicModel.js` | | 2 | Multi-parent registration is allowed but not exercised in production tests. | `CONTRACT.md` — Children registered by this node | | 3 | `set.position` move sequences are interruptible but tests cover happy-path only; abort-deadlock edge case documented separately. | `state.js` abort logic + `test/integration/` | | 4 | `execSequence` (legacy umbrella topic) will be removed in Phase 7 — callers must migrate to `cmd.startup` / `cmd.shutdown` / `cmd.estop`. | `CONTRACT.md` — execSequence demux |