## 1. What this node is
2026-05-11 21:06:26 +02:00
**valve** models a single actuated throttling valve at the S88 Equipment Module level. It loads a supplier Kv-vs-position characteristic curve, drives an FSM for open/close move sequences (using `accelerating` /`decelerating` states shared with `rotatingMachine` ), and recomputes pressure drop from flow + Kv via a hydraulic model. Used standalone or as a child of `valveGroupControl` .
2026-05-11 15:17:38 +02:00
## 2. Position in the platform
```mermaid
flowchart LR
vgc[valveGroupControl<br/>Unit]:::unit -->|set.position| this[valve<br/>Equipment]:::equip
2026-05-11 21:06:26 +02:00
src["machine / MGC / PS<br/>(upstream source)"]:::unit -->|child.register| this
meas[measurement<br/>type=pressure / flow]:::ctrl -.->|data| this
this -->|child.register Port 2| vgc
2026-05-11 15:17:38 +02:00
this -->|evt.deltaPChange| vgc
2026-05-11 21:06:26 +02:00
this -->|evt.fluidCompatibilityChange| vgc
2026-05-11 15:17:38 +02:00
classDef unit fill:#50a8d9 ,color:#000
classDef equip fill:#86bbdd ,color:#000
classDef ctrl fill:#a9daee ,color:#000
```
2026-05-11 21:06:26 +02:00
S88 colours: Unit `#50a8d9` , Equipment `#86bbdd` , Control Module `#a9daee` . Source: `.claude/rules/node-red-flow-layout.md` .
2026-05-11 15:17:38 +02:00
## 3. Capability matrix
| Capability | Status | Notes |
|---|---|---|
| Predicts deltaP from flow + Kv | ✅ | Hydraulic model picks liquid vs gas formula per `serviceType` . |
2026-05-11 21:06:26 +02:00
| Loads supplier curve by model name | ✅ | `asset.model` resolved through `loadModel` ; inline `valveCurve` override supported. |
| Position move FSM | ✅ | `accelerating` / `decelerating` states with interruptible setpoints; `moveTo` uses shared state machine. |
| Startup / shutdown sequences | ✅ | Pre-shutdown ramps valve to position 0 before executing stop sequence. |
| Emergency-stop sequence | ✅ | `cmd.estop` → `emergencystop → off` sequence. |
| Fluid-contract aggregation | ✅ | Tracks upstream service type via registered sources through `FluidCompatibility` . |
| Gas-choke detection | ⚠️ | Hard cap at `gasChokedRatioLimit` ; surfaced in `hydraulicDiagnostics` . |
2026-05-11 15:17:38 +02:00
| Multi-parent registration | ⚠️ | Allowed but not exercised in production tests. |
## 4. Code map
```mermaid
flowchart TB
subgraph nodeRED["nodeClass.js — adapter (BaseNodeAdapter)"]
2026-05-11 21:06:26 +02:00
nc["buildDomainConfig()<br/>static DomainClass=Valve, commands<br/>tickInterval=null (event-driven)"]
2026-05-11 15:17:38 +02:00
end
subgraph domain["specificClass.js — orchestrator (BaseDomain)"]
2026-05-11 21:06:26 +02:00
sc["Valve.configure()<br/>wires concern modules<br/>overrides registerChild → FluidCompatibility"]
2026-05-11 15:17:38 +02:00
end
subgraph concerns["src/ concern modules"]
state["state/<br/>stateBindings → positionChange"]
fluid["fluid/<br/>FluidCompatibility"]
curve["curve/<br/>SupplierCurvePredictor"]
meas["measurement/<br/>MeasurementRouter + FORMULA_UNITS"]
flow["flow/<br/>FlowController (setpoint, sequences)"]
io["io/<br/>buildOutput + buildStatusBadge"]
hyd["hydraulicModel.js<br/>ValveHydraulicModel"]
end
nc --> sc
sc --> state
sc --> fluid
sc --> curve
sc --> meas
sc --> flow
sc --> io
sc --> hyd
```
| Module | Owns | Read first if you're changing… |
|---|---|---|
2026-05-11 21:06:26 +02:00
| `state/` | Bindings from state-machine `positionChange` → `updatePosition()` | Move-finished triggers, position callbacks. |
| `fluid/` | Service-type compatibility, contract aggregation | Gas-vs-liquid mismatch warnings, upstream fluid tracking. |
| `curve/` | Supplier Kv curve load + interpolation | Curve fitting, model selection, density keys. |
| `measurement/` | Pressure/flow routing + deltaP recompute | What triggers a recalc, measurement container writes. |
| `flow/` | Sequence + setpoint execution, mode validation | Startup / shutdown / move semantics, allowed-source checks. |
2026-05-11 15:17:38 +02:00
| `io/` | Port-0 output shape + status badge | What lands on the wire each tick. |
2026-05-11 21:06:26 +02:00
| `hydraulicModel.js` | Liquid + gas deltaP formulas, choke detection | Hydraulic calculation errors, choke ratio behaviour. |
2026-05-11 15:17:38 +02:00
## 5. Topic contract
> **Auto-generated** from `src/commands/index.js`. Do NOT hand-edit between the markers. Re-run `npm run wiki:contract`.
<!-- BEGIN AUTOGEN: topic-contract -->
2026-05-11 19:44:14 +02:00
| Canonical topic | Aliases | Payload | Unit | Effect |
|---|---|---|---|---|
| `set.mode` | `setMode` | `string` | — | Switch the valve between auto / manual control modes. |
| `cmd.startup` | _ (none) _ | `any` | — | Initiate the valve startup sequence. |
| `cmd.shutdown` | _ (none) _ | `any` | — | Initiate the valve shutdown sequence. |
| `cmd.estop` | `emergencystop` , `emergencyStop` | `any` | — | Trigger an emergency stop on the valve. |
| `execSequence` | _ (none) _ | `object` | — | Legacy umbrella that demuxes payload.action to startup / shutdown / estop. |
| `set.position` | `execMovement` | `object` | — | Move the valve to a control-% position via execMovement. |
| `data.flow` | `updateFlow` | `object` | — | Push a measured flow into the valve (variant + position + unit). |
| `query.curve` | `showcurve` | `any` | — | Return the valve characteristic curve on the reply port. |
| `child.register` | `registerChild` | `string` | — | Register a child measurement with this valve. |
2026-05-11 15:17:38 +02:00
<!-- END AUTOGEN: topic-contract -->
## 6. Child registration
2026-05-11 21:06:26 +02:00
valve overrides `BaseDomain.registerChild` with `FluidCompatibility.registerChild` . Upstream sources feed the fluid-contract aggregator; measurement children attach through the standard measurement handshake and land in `MeasurementRouter` .
2026-05-11 15:17:38 +02:00
```mermaid
flowchart LR
subgraph kids["accepted children (softwareType)"]
2026-05-11 21:06:26 +02:00
src["machine / rotatingmachine<br/>machinegroup / pumpingstation<br/>valvegroupcontrol"]:::unit
m["measurement<br/>type=pressure or flow"]:::ctrl
2026-05-11 15:17:38 +02:00
end
src -->|getFluidContract| fluid[FluidCompatibility<br/>aggregates serviceType]
m -->|"<type>.measured.<position>"| router[MeasurementRouter<br/>updatePressure / updateFlow]
router --> deltaP[updateDeltaP<br/>writes pressure.predicted.delta]
2026-05-11 21:06:26 +02:00
fluid --> evt1["evt.fluidCompatibilityChange<br/>evt.fluidContractChange"]
2026-05-11 15:17:38 +02:00
deltaP --> evt2[evt.deltaPChange]
classDef unit fill:#50a8d9 ,color:#000
classDef ctrl fill:#a9daee ,color:#000
```
| softwareType | onRegister side-effect | Subscribed events |
|---|---|---|
2026-05-11 21:06:26 +02:00
| `machine` / `rotatingmachine` | Stored as upstream source; reads `getFluidContract()` or defaults to `liquid` . | `fluidContractChange` |
| `machinegroup` / `machinegroupcontrol` | Same; recomputes aggregate service type. | `fluidContractChange` |
| `pumpingstation` | Same. | `fluidContractChange` |
| `valvegroupcontrol` | Same. | `fluidContractChange` |
| `measurement` | Routed via measurement handshake; values land in `MeasurementContainer` . | `<type>.measured.<position>` |
2026-05-11 15:17:38 +02:00
## 7. Lifecycle — what one event does
```mermaid
sequenceDiagram
participant parent as valveGroupControl
participant valve as valve
2026-05-11 21:06:26 +02:00
participant fsm as state FSM
2026-05-11 15:17:38 +02:00
participant hyd as hydraulicModel
participant out as Port-0
parent->>valve: set.position { setpoint: 60 }
2026-05-11 21:06:26 +02:00
valve->>fsm: moveTo(60)
fsm-->>fsm: operational → accelerating
fsm-->>valve: positionChange ticks (stateBindings)
2026-05-11 15:17:38 +02:00
valve->>valve: predictKv(position)
valve->>hyd: calculateDeltaPMbar(q, kv, downP, rho, T)
2026-05-11 21:06:26 +02:00
hyd-->>valve: { deltaPMbar, diagnostics }
2026-05-11 15:17:38 +02:00
valve->>valve: write pressure.predicted.delta
valve->>parent: emitter.emit('deltaPChange', deltaP)
2026-05-11 21:06:26 +02:00
valve->>out: msg { topic, payload (delta-compressed) }
fsm-->>fsm: accelerating → operational (setpoint reached)
2026-05-11 15:17:38 +02:00
```
## 8. Data model — `getOutput()`
What lands on Port 0. Composed in `io/output.buildOutput` , then delta-compressed by `outputUtils.formatMsg` .
<!-- BEGIN AUTOGEN: data-model -->
| Key | Type | Unit | Sample |
|---|---|---|---|
| `state` | string | — | `"operational"` |
| `percentageOpen` | number | % | `0` |
| `moveTimeleft` | number | s | `0` |
| `mode` | string | — | `"auto"` |
| `downstream_predicted_flow` | number | m3/h | `0` |
| `downstream_measured_flow` | number | m3/h | _ (emitted when measurement child present) _ |
| `downstream_predicted_pressure` | number | mbar | _ (emitted when upstream pressure present) _ |
| `downstream_measured_pressure` | number | mbar | _ (emitted when measurement child present) _ |
| `delta_predicted_pressure` | number | mbar | `0` |
<!-- END AUTOGEN: data-model -->
2026-05-11 21:06:26 +02:00
Measurement keys follow the legacy `<position>_<variant>_<type>` shape (e.g. `downstream_predicted_flow` , `delta_predicted_pressure` ). Only keys with finite values are emitted — consumers must cache and merge (delta-compression is active).
2026-05-11 15:17:38 +02:00
## 9. Configuration — editor form ↔ config keys
```mermaid
flowchart TB
subgraph editor["Node-RED editor form"]
2026-05-11 21:06:26 +02:00
f1[Reaction Speed]
f2[Asset model / supplier / category]
2026-05-11 15:17:38 +02:00
f3[Service type]
2026-05-11 21:06:26 +02:00
f4[Fluid density / temperature K]
f5[Gas choke ratio limit]
f6[Startup / warmup / shutdown / cooldown times]
f7[Log level / enableLog]
f8[positionVsParent]
2026-05-11 15:17:38 +02:00
end
subgraph config["Domain config slice"]
2026-05-11 21:06:26 +02:00
c1["movement.speed (stateConfig)"]
2026-05-11 15:17:38 +02:00
c2[asset.model]
2026-05-11 21:06:26 +02:00
c3["runtimeOptions.serviceType → hydraulicModel"]
c4["runtimeOptions.fluidDensity / fluidTemperatureK"]
c5["runtimeOptions.gasChokedRatioLimit"]
c6["stateConfig.time.starting / warmingup / stopping / coolingdown"]
c7["general.logging.enabled / logLevel"]
c8["functionality.positionVsParent → Port-2 registration"]
2026-05-11 15:17:38 +02:00
end
f1 --> c1
f2 --> c2
f3 --> c3
f4 --> c4
f5 --> c5
f6 --> c6
2026-05-11 21:06:26 +02:00
f7 --> c7
f8 --> c8
2026-05-11 15:17:38 +02:00
```
2026-05-11 21:06:26 +02:00
| Form field | Config path | Default | Range / type | Where used |
2026-05-11 15:17:38 +02:00
|---|---|---|---|---|
2026-05-11 21:06:26 +02:00
| Reaction Speed | `movement.speed` (stateConfig) | `1` | > 0 (%/s) | `MovementManager` — sets rate of position change |
| Asset model | `asset.model` | `'Unknown'` | string | `SupplierCurvePredictor` — selects Kv curve dataset |
| Service type | `runtimeOptions.serviceType` | `null` (from asset) | `'gas'` / `'liquid'` | `ValveHydraulicModel` formula selection |
| Fluid density | `runtimeOptions.fluidDensity` | model default | > 0 (kg/m³) | liquid hydraulic formula |
| Fluid temperature | `runtimeOptions.fluidTemperatureK` | model default | > 0 (K) | gas hydraulic formula |
| Gas choke limit | `runtimeOptions.gasChokedRatioLimit` | per asset | 0– 1 | gas choke cap in `ValveHydraulicModel` |
| Startup time | `stateConfig.time.starting` | `10` s | > 0 (s) | `StateManager` transition timer |
| Warmup time | `stateConfig.time.warmingup` | `5` s | > 0 (s) | `StateManager` protected transition |
| Shutdown time | `stateConfig.time.stopping` | `5` s | > 0 (s) | `StateManager` transition timer |
| Cooldown time | `stateConfig.time.coolingdown` | `10` s | > 0 (s) | `StateManager` transition timer |
| Mode | `mode.current` | `'auto'` | `auto` / `virtualControl` / `fysicalControl` / `maintenance` | `FlowController.isValidSourceForMode` |
| Log level | `general.logging.logLevel` | `'info'` | enum | structured logger |
| positionVsParent | `functionality.positionVsParent` | `'atEquipment'` | enum | Port-2 registration message to parent |
2026-05-11 15:17:38 +02:00
## 10. State chart
```mermaid
stateDiagram-v2
[*] --> off
2026-05-11 21:06:26 +02:00
off --> idle : cmd.startup (boot sequence)
off --> emergencystop : cmd.estop
off --> maintenance : set.mode=maintenance
idle --> starting : cmd.startup
idle --> off : (direct transition)
idle --> emergencystop : cmd.estop
idle --> maintenance : set.mode=maintenance
starting --> warmingup : timed (starting duration)
starting --> emergencystop : cmd.estop
warmingup --> operational : timed (warmup duration) [protected — cannot abort]
warmingup --> emergencystop : cmd.estop
operational --> accelerating : set.position > current
operational --> decelerating : set.position < current
operational --> stopping : cmd.shutdown
operational --> emergencystop : cmd.estop
accelerating --> operational : setpoint reached
accelerating --> emergencystop : cmd.estop
decelerating --> operational : setpoint reached
decelerating --> emergencystop : cmd.estop
stopping --> coolingdown : timed (stopping duration)
stopping --> idle : (direct)
stopping --> emergencystop : cmd.estop
coolingdown --> idle : timed (cooldown duration) [protected — cannot abort]
coolingdown --> off : (direct)
coolingdown --> emergencystop : cmd.estop
emergencystop --> idle : cmd.reset / sequence
emergencystop --> off : cmd.reset / sequence
emergencystop --> maintenance : (allowed)
maintenance --> idle : manual reset
maintenance --> off : manual reset
2026-05-11 15:17:38 +02:00
```
2026-05-11 21:06:26 +02:00
**Key valve-specific behaviours:**
- `accelerating` = position moving up; `decelerating` = position moving down. Both fire `positionChange` ticks. The valve's `stateBindings` hooks these to `updatePosition()` → Kv lookup → deltaP recompute.
- `warmingup` and `coolingdown` are **protected ** — the abort signal is disabled; these phases cannot be interrupted.
- `cmd.shutdown` from `operational` first ramps the valve to position 0 (via `FlowController.executeSequence('shutdown')` ), then transitions `stopping → coolingdown → idle` .
- `cmd.estop` triggers `emergencystop → off` regardless of current state (except from within protected transitions).
- Default sequences: `startup` = `[starting, warmingup, operational]` ; `boot` = `[idle, starting, warmingup, operational]` ; `emergencystop` = `[emergencystop, off]` .
2026-05-11 15:17:38 +02:00
## 11. Examples
| Tier | File | What it shows | Mandatory? |
|---|---|---|---|
2026-05-11 21:06:26 +02:00
| Basic | `examples/basic.flow.json` | Inject `set.position` + minimal wiring, no parent | ✅ |
| Integration | `examples/integration.flow.json` | valve + VGC + upstream measurement source | ✅ |
| Edge | `examples/edge.flow.json` | Edge-case inputs (gas, choke, estop, bad setpoints) | ⭕ optional |
2026-05-11 15:17:38 +02:00
2026-05-11 21:06:26 +02:00
Renamed example files (`01-Basic.flow.json` , `02-Integration.flow.json` , `03-Dashboard.flow.json` ) will replace the above when produced. Screenshots under `wiki/_partial-screenshots/valve/` . Docker compose snippet under `examples/README.md` .
2026-05-11 15:17:38 +02:00
## 12. Debug recipes
| Symptom | First thing to check | Where to look |
|---|---|---|
2026-05-11 21:06:26 +02:00
| Status badge shows `⚠ no input` | Did any pressure / flow measurement register? Watch Port 2. | Debug tap on Port 2 |
| `delta_predicted_pressure` stuck at `0` | Is `kv > 0` ? FSM may be in `off` / `idle` — valve is closed. | `state.getCurrentState()` , `percentageOpen` |
| Gas mismatch warning on status badge | `fluidCompatibility.status` is `mismatch` or `conflict` . | `getFluidCompatibility()` |
| `query.curve` returns empty curve | `asset.model` not found by `loadModel` ; check `SupplierCurvePredictor.snapshot()` . | `SupplierCurvePredictor.snapshot()` |
| deltaP non-finite | Downstream gauge pressure absolute term ≤ 0, or choked ratio reached. | `hydraulicDiagnostics` in output |
| `set.position` has no effect | Check `currentMode` — source may not be in `mode.allowedSources[mode]` . | `FlowController.isValidSourceForMode` |
| FSM stuck in `accelerating` / `decelerating` | Movement was aborted but `_returnToOperationalOnAbort` was false. Send a new `set.position` . | `state.js` abort logic |
2026-05-11 15:17:38 +02:00
> Never ship `enableLog: 'debug'` in a demo — fills the container log within seconds and obscures real errors. Use only for live debugging.
## 13. When you would NOT use this node
2026-05-11 21:06:26 +02:00
- Use valve for a **throttling actuator ** with a known Kv curve. For a fixed-restriction orifice (no actuator, no curve), model the deltaP externally.
- Don't use valve to model a **non-return / check valve ** — no position control or FSM-driven actuation is exposed.
- Skip valve when an upstream source already provides flow directly and **no pressure-drop estimate is needed ** — wire the source straight to the parent without inserting a valve.
2026-05-11 15:17:38 +02:00
## 14. Known limitations / current issues
| # | Issue | Tracked in |
|---|---|---|
| 1 | Gas-choke detection is a hard cap, not a smooth transition — chart traces show a step at the choked-ratio limit. | `hydraulicModel.js` |
2026-05-11 21:06:26 +02:00
| 2 | Multi-parent registration is allowed but not exercised in production tests. | `CONTRACT.md` — Children registered by this node |
| 3 | `set.position` move sequences are interruptible but tests cover happy-path only; abort-deadlock edge case documented separately. | `state.js` abort logic + `test/integration/` |
| 4 | `execSequence` (legacy umbrella topic) will be removed in Phase 7 — callers must migrate to `cmd.startup` / `cmd.shutdown` / `cmd.estop` . | `CONTRACT.md` — execSequence demux |