The operating-point series (flow.predicted.{downstream,atequipment},
power.predicted.atequipment) were only written by calcFlow/calcPower while
operational, or by _updateState on a state transition. A machine that boots
into idle and never runs therefore emitted these keys NEVER — so InfluxDB
carried only the flow envelope (max/min) and dashboard panels querying the
operating point rendered blank, unable to show even the off/0 state.
Seed them to 0 in _init() alongside max/min, so telemetry always carries the
operating point: 0 while idle, real values once the pump runs. Verified end to
end: keys now present in InfluxDB, the Grafana flow panel resolves, and the
real prediction path produces non-zero values (~98 m3/h, ~13 kW) that flow
through getOutput to Port 1.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
specificClass._setupCurves now calls assetResolver.resolveAssetMetadata
to derive supplier/type/units from the model id, instead of trusting
denormalized fields on the node config. If the model isn't in the
registry, installs a null-predictor stub and logs a clear "pick a model
from the asset menu" error rather than crashing.
rotatingMachine.html: defaults block trimmed (supplier/category/assetType
were stale copies of registry data).
Tests:
- New test/basic/assetMetadata.basic.test.js covers the registry-resolve
path and the missing-model fallback.
- nodeClass-config / error-paths / nodeClass-routing / factories /
abort-deadlock fixtures updated to the trimmed asset shape.
- 209/209 tests pass.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
For all 11 nodes with auto-gen markers: wiki/Home.md sections 5 (topic
contract) and 9 (data model) regenerated via npm run wiki:all. New
Unit column shows '<measure> (default <unit>)' for declared topics,
'—' otherwise. Effect column now uses descriptor.description (P11.2
field) overriding the generic per-prefix fallback.
For rotatingMachine + reactor: Phase 10 test rewrites — 3 + 8 files
moved off private nodeClass internals (_attachInputHandler, _commands,
_pendingExtras, _registerChild, _tick, etc.) to the public
BaseNodeAdapter surface (node.handlers.input, node.source.*).
+6 / +7 net new tests.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Same as MGC — UnitPolicy property bags replace the manual _unitView/
unitPolicyView reassignment. specificClass.js 400→377. 196/196 tests
still pass.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Safety:
- Async input handler: await all handleInput() calls, prevents unhandled rejections
- Fix emergencyStop case mismatch: "emergencyStop" → "emergencystop" matching config
- Implement showCoG() method (was routing to undefined)
- Null guards on 6 methods for missing curve data
- Editor menu polling timeout (5s max)
- Listener cleanup on node close (child measurements + state emitter)
- Tick loop race condition: track startup timeout, clear on close
Prediction accuracy:
- Remove efficiency rounding that destroyed signal in canonical units
- Fix calcEfficiency variant: hydraulic power reads from correct variant
- Guard efficiency calculations against negative/zero values
- Division-by-zero protection in calcRelativeDistanceFromPeak
- Curve data anomaly detection (cross-pressure median-y ratio check)
- calcEfficiencyCurve O(n²) → O(n) with running min
- updateCurve bootstraps predictors when they were null
Tests: 43 new tests (76 total) covering emergency stop, shutdown/maintenance
sequences, efficiency/CoG, movement lifecycle, output format, null guards,
and listener cleanup.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>