znetsixe
2dd419dbf4 Editor: nudge dashed lines themselves, revert tank height
Reverts the tank-bigger approach from last commit. Instead of
scaling the tank and keeping strict proportionality, the dashed
threshold lines are now nudged apart directly so each gets a
guaranteed 36-px vertical gap. Inputs and labels align with the
lines (no more leader lines needed).

Trade-off: the diagram is now an ordered schematic, not a strictly
to-scale rendering. Values are still shown next to each line via
the input boxes, and the value ordering is preserved. For an editor
where the goal is entering parameters, readability wins over scale
fidelity.

Sizing reverted:
  viewBox    620 → 430
  tank h     520 → 340
  botY       560 → 380

Behavior:
  GAP        30 → 36 (more visible space between dashed lines)
  placeItem  takes a single y now (line + input + label + unit
             share it); leader-line mechanism kept as hidden
             plumbing in case we switch back to proportional later

Dead-volume band now anchors to the (possibly-nudged) outflow line
instead of the proportional y so it still visually meets the line
cleanly.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-23 12:10:23 +02:00
znetsixe
785d036dc6 Editor: taller tank — more vertical room between threshold lines
Tank height 340 → 520 px (viewBox 480 → 620). Lines that were
cramped in the bottom metre now have ~50 % more room, so:

- The Outlet arrow no longer visually crowds the minLevel line
- Dashed threshold lines (dryRunLevel, minLevel, outflowLevel)
  have visible breathing room between them for typical wastewater
  values where they sit in the bottom 1 m
- Input-stack GAP bumped 26 → 30 px to match the extra vertical
  real estate

Pure layout change — same proportional mapping, same nudging
algorithm, just more canvas. Floor/datum label and ordering-
warning ribbon positions shifted accordingly.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-23 11:41:03 +02:00
znetsixe
65fe68b87f Editor: nudge crowded threshold inputs off their lines with leader lines
When real wastewater values cluster near the basin floor (minLevel,
dryRunLevel, outflowLevel are often within a few cm of each other),
the threshold inputs were stacking on top of each other. Now:

- Threshold LINE stays at its proportional y on the tank (visual
  truth: that's where the level actually is).
- Input BOX / label / unit are positioned in a nudged right-column
  stack with a minimum 26-px gap so they never overlap.
- A dashed grey leader line connects each line to its input when
  they had to be pulled apart, so the association stays visible.
- Items are sorted by ideal y top-down and nudged downward once;
  basinHeight is pinned at the rim and acts as the anchor.

Also: viewBox extended 430 → 480 so the bottom-of-stack items have
room below the tank when the bottom cluster is tight. Warning ribbon
moved to y=460 accordingly.

No schema change; purely UI layout.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-23 10:41:16 +02:00
znetsixe
d641d2248d Editor: interactive basin diagram — inputs placed at each threshold line
Replaces the static parameters-diagram-above-form-rows layout with a
single interactive SVG where every threshold input sits directly on
the tank at its proportional y-position. Typing a value repositions
the corresponding line + input + label live.

What moved into the diagram (via <foreignObject> holding real
<input> elements with their existing node-input-* IDs so Node-RED
save/restore is untouched):

  basinHeight    — top of tank (fixed at rim by definition)
  overflowLevel  — weir crest (red, dashed)
  maxLevel       — 100 % demand line (orange, dashed)
  startLevel     — ramp-start line (green, dashed)
  minLevel       — MGC-shutdown line (purple, dashed)
  inflowLevel    — Inlet arrow + input on left
  outflowLevel   — Outlet arrow + input on right
  dryRunLevel    — read-only, computed from outflow × (1+dryRunPct/100)

Also in the diagram:
- Dead-volume band fills the area below outflowLevel dynamically
- Warning ribbon appears below the tank if ordering invariants break
  (mirrors specificClass._validateThresholdOrdering)
- All positions scale against the user's basinHeight; if empty, a
  default 5 m scale is used just to keep the diagram readable

What stayed as regular form rows:
- Basin Volume (m³) — not a height, can't be placed on a y-axis
- minLevel / startLevel / maxLevel were in the Control Strategy >
  Level-based section; removed from there and moved into the diagram
  (the level-based subsection now contains a one-line pointer)
- Safety % inputs (dryRun, overfill) stay in the Safety section with
  their derived-level readouts, now synced with the diagram

No schema changes, no field additions, no behaviour changes in the
runtime. Pure editor-UX.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-23 10:28:18 +02:00
znetsixe
12904b4902 Editor: inline parameters diagram at top of Basin Geometry
~3 KB inline SVG showing the 5 threshold lines + inlet/outlet pipe
arrows + floor datum, using the same names as the editor fields
(basinHeight, overflowLevel, maxLevel, startLevel, minLevel,
dryRunLevel). No new inputs — purely a visual reminder of what
each field refers to, so operators don't have to alt-tab to the
wiki to figure out which pipe edge to measure.

Wrapped in <details open> so users can collapse it once they
know the layout — no forced scroll through the diagram on every
edit session.

Matches the vocabulary in wiki/diagrams/basin-model.drawio.svg
(inlet = bottom of pipe, outlet = top of pipe, 0 m datum at
basin floor, dryRunLevel derived from %).

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-23 10:19:23 +02:00
znetsixe
1ebbcb62cc Editor: pipe-edge conventions + live derived safety levels
### P1 — match diagram naming (labels only, no schema change)

- "Inlet Elevation"    → "Inlet (bottom of pipe, m)"
- "Outlet Elevation"   → "Outlet (top of pipe, m)"
- "Overflow Level"     → "Overflow (weir crest, m)"
- "Basin Bottom (m Refheight)" → "Basin floor above datum (m)"
- Added a one-line banner at the top of Basin Geometry:
  "All heights measured from the basin floor (0 m)."

These map directly to the clarifications added to basin-model.drawio.svg
so editor and diagram speak the same vocabulary.

### P3 — live derived safety levels next to the % fields

Low/High Volume Threshold fields now show the resulting trip level
live as the operator types:

  Low Volume Threshold (%)  [ 2  ]  → dryRunLevel ≈ 0.21 m
  High Volume Threshold (%) [ 98 ]  → overfillLevel ≈ 4.41 m

Recomputed on every input/change of outflowLevel, inflowLevel,
overflowLevel, minHeightBasedOn, or either %. Pure UI feedback —
no schema change, no save-side change, same formulas as
specificClass._validateThresholdOrdering().

Also includes the user's latest basin-model.drawio.svg update
(inlet=bottom/outlet=top labels + datum annotation).

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-23 09:58:17 +02:00
znetsixe
a2189457f6 Rename basin/control thresholds to wiki naming; trim stale comments
Aligns the code with the 5-threshold convention used throughout the
wiki (basin model + per-mode transfer-function diagrams):

  heightInlet       → inflowLevel
  heightOutlet      → outflowLevel
  heightOverflow    → overflowLevel
  stopLevel         → minLevel
  maxFlowLevel      → maxLevel
  minFlowLevel      → removed (collapsed into startLevel; they were
                      always supposed to hold the same value)
  minVolIn          → minVolAtInflow
  minVolOut         → minVolAtOutflow
  maxVolOverflow    → maxVolAtOverflow
  startLevel        → unchanged

Config schema (generalFunctions/src/configs/pumpingStation.json) is
updated in a parallel commit in that submodule.

Also:
- Stripped the ~150-line ASCII basin diagram from initBasinProperties
  JSDoc; it now points at wiki/functional-description.md#basin-model.
- Trimmed the top-of-class JSDoc — the config-sections breakdown was
  drifting from the schema anyway; wiki is now the source of truth.
- Tidied inline comments in _controlLevelBased, _scaleLevelToFlowPercent.
- Editor order reshuffled to match the bottom→top basin order:
  minLevel, startLevel, maxLevel.

Breaking change for saved flows: existing pumpingStation nodes in
production flows reference the old field names and will need to be
re-entered in the editor. No compat shim — node is RnD/trial.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-22 16:13:59 +02:00
znetsixe
7d05d37678 Merge commit '762770a' into HEAD
# Conflicts:
#	pumpingStation.html
#	src/nodeClass.js
#	src/specificClass.js
2026-03-31 18:20:09 +02:00
Rene De Ren
762770a063 Expose output format selectors in editor 2026-03-12 16:39:25 +01:00
znetsixe
288bd244dd updating to corrospend with reality 2025-11-27 17:46:24 +01:00
znetsixe
d91609b3a4 updates to safety features 2025-11-25 14:57:39 +01:00
znetsixe
5a575a29fe updated pumpingstation 2025-11-20 12:15:46 +01:00
znetsixe
f29aa4f5af latest version 2025-10-21 12:45:19 +02:00
znetsixe
eabaa1b0bf writing core class 2025-10-14 16:32:44 +02:00
znetsixe
d94d5874bc updated pumping station to match stack 2025-10-14 13:51:32 +02:00
znetsixe
fa30be5e2d Changed names 2025-10-14 08:36:45 +02:00