change(ps): emit output flow in m³/s
Set UnitPolicy output flow/netFlowRate to m³/s (was m³/h).
NOTE: this reverts the output-unit half of e041877 ("keep canonical
flow in m³/s, emit output in m³/h"). Committed at user direction during
dev-lzm → development integration; flagged for review against the
documented PS units decision.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -32,7 +32,7 @@ class PumpingStation extends BaseDomain {
|
|||||||
static unitPolicy = UnitPolicy.declare({
|
static unitPolicy = UnitPolicy.declare({
|
||||||
canonical: { flow: 'm3/s', pressure: 'Pa', power: 'W', temperature: 'K' },
|
canonical: { flow: 'm3/s', pressure: 'Pa', power: 'W', temperature: 'K' },
|
||||||
output: {
|
output: {
|
||||||
flow: 'm3/h', netFlowRate: 'm3/h', level: 'm', volume: 'm3',
|
flow: 'm3/s', netFlowRate: 'm3/s', level: 'm', volume: 'm3',
|
||||||
overflowVolume: 'm3', underflowVolume: 'm3',
|
overflowVolume: 'm3', underflowVolume: 'm3',
|
||||||
},
|
},
|
||||||
requireUnitForTypes: [],
|
requireUnitForTypes: [],
|
||||||
|
|||||||
Reference in New Issue