feat(commands): unit shorthand + collapse duplicated value/unit parsing; wiki sync
- 5 descriptors -> unit: shorthand (cmd.calibrate.volume/level, set.inflow/ outflow/demand). - setInflow/setOutflow: drop the hand-rolled scalar-vs-object parsing — the registry now normalises every shape to a number in the descriptor unit; the handlers become guarded one-liners (matching setDemand). - Regenerate wiki topic-contract + command-envelope note (msg.origin). 143/143 tests green. Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -48,42 +48,29 @@ exports.calibrateLevel = (source, msg, ctx) => {
|
|||||||
source.calibratePredictedLevel(v);
|
source.calibratePredictedLevel(v);
|
||||||
};
|
};
|
||||||
|
|
||||||
exports.setInflow = (source, msg) => {
|
// The registry has already normalised any accepted shape (number, numeric
|
||||||
// Payload is either a number (legacy q_in shape) or
|
// string, or { value, unit } object) to a number in the descriptor unit
|
||||||
// { value, unit, timestamp } (richer object form).
|
// (m3/h) and tagged msg.unit. Handlers just read the normalised scalar.
|
||||||
const p = msg.payload;
|
exports.setInflow = (source, msg, ctx) => {
|
||||||
let value;
|
const log = _logger(source, ctx);
|
||||||
let unit;
|
const value = Number(msg.payload);
|
||||||
let timestamp;
|
if (!Number.isFinite(value)) {
|
||||||
if (p !== null && typeof p === 'object') {
|
log?.warn?.(`set.inflow: non-numeric payload '${JSON.stringify(msg.payload)}'`);
|
||||||
value = Number(p.value);
|
return;
|
||||||
unit = p.unit;
|
|
||||||
timestamp = p.timestamp || Date.now();
|
|
||||||
} else {
|
|
||||||
value = Number(p);
|
|
||||||
unit = msg?.unit;
|
|
||||||
timestamp = msg?.timestamp || Date.now();
|
|
||||||
}
|
}
|
||||||
source.setManualInflow(value, timestamp, unit);
|
source.setManualInflow(value, msg.timestamp, msg.unit);
|
||||||
};
|
};
|
||||||
|
|
||||||
exports.setOutflow = (source, msg) => {
|
exports.setOutflow = (source, msg, ctx) => {
|
||||||
// Manual q_out — basin-docs dashboard injects a drain rate without
|
// Manual q_out — basin-docs dashboard injects a drain rate without wiring a
|
||||||
// wiring a real pump. Same payload shape as q_in.
|
// real pump. Same normalised shape as set.inflow.
|
||||||
const p = msg.payload;
|
const log = _logger(source, ctx);
|
||||||
let value;
|
const value = Number(msg.payload);
|
||||||
let unit;
|
if (!Number.isFinite(value)) {
|
||||||
let timestamp;
|
log?.warn?.(`set.outflow: non-numeric payload '${JSON.stringify(msg.payload)}'`);
|
||||||
if (p !== null && typeof p === 'object') {
|
return;
|
||||||
value = Number(p.value);
|
|
||||||
unit = p.unit;
|
|
||||||
timestamp = p.timestamp || Date.now();
|
|
||||||
} else {
|
|
||||||
value = Number(p);
|
|
||||||
unit = msg?.unit;
|
|
||||||
timestamp = msg?.timestamp || Date.now();
|
|
||||||
}
|
}
|
||||||
source.setManualOutflow(value, timestamp, unit);
|
source.setManualOutflow(value, msg.timestamp, msg.unit);
|
||||||
};
|
};
|
||||||
|
|
||||||
exports.setDemand = (source, msg, ctx) => {
|
exports.setDemand = (source, msg, ctx) => {
|
||||||
|
|||||||
@@ -26,9 +26,10 @@ module.exports = [
|
|||||||
{
|
{
|
||||||
topic: 'cmd.calibrate.volume',
|
topic: 'cmd.calibrate.volume',
|
||||||
aliases: ['calibratePredictedVolume'],
|
aliases: ['calibratePredictedVolume'],
|
||||||
// any: payload may be a number or numeric string.
|
// any: payload may be a number, numeric string, or { value, unit } object —
|
||||||
|
// the registry normalises all of them to a number in `unit` before the handler.
|
||||||
payloadSchema: { type: 'any' },
|
payloadSchema: { type: 'any' },
|
||||||
units: { measure: 'volume', default: 'm3' },
|
unit: 'm3',
|
||||||
description: 'Calibrate the predicted-volume integrator to a known basin volume.',
|
description: 'Calibrate the predicted-volume integrator to a known basin volume.',
|
||||||
handler: handlers.calibrateVolume,
|
handler: handlers.calibrateVolume,
|
||||||
},
|
},
|
||||||
@@ -36,16 +37,15 @@ module.exports = [
|
|||||||
topic: 'cmd.calibrate.level',
|
topic: 'cmd.calibrate.level',
|
||||||
aliases: ['calibratePredictedLevel'],
|
aliases: ['calibratePredictedLevel'],
|
||||||
payloadSchema: { type: 'any' },
|
payloadSchema: { type: 'any' },
|
||||||
units: { measure: 'length', default: 'm' },
|
unit: 'm',
|
||||||
description: 'Calibrate the predicted-volume integrator to a known basin level.',
|
description: 'Calibrate the predicted-volume integrator to a known basin level.',
|
||||||
handler: handlers.calibrateLevel,
|
handler: handlers.calibrateLevel,
|
||||||
},
|
},
|
||||||
{
|
{
|
||||||
topic: 'set.inflow',
|
topic: 'set.inflow',
|
||||||
aliases: ['q_in'],
|
aliases: ['q_in'],
|
||||||
// any: number, numeric string, or { value, unit, timestamp } object.
|
|
||||||
payloadSchema: { type: 'any' },
|
payloadSchema: { type: 'any' },
|
||||||
units: { measure: 'volumeFlowRate', default: 'm3/h' },
|
unit: 'm3/h',
|
||||||
description: 'Push a measured inflow value into the basin balance.',
|
description: 'Push a measured inflow value into the basin balance.',
|
||||||
handler: handlers.setInflow,
|
handler: handlers.setInflow,
|
||||||
},
|
},
|
||||||
@@ -53,7 +53,7 @@ module.exports = [
|
|||||||
topic: 'set.outflow',
|
topic: 'set.outflow',
|
||||||
aliases: ['q_out'],
|
aliases: ['q_out'],
|
||||||
payloadSchema: { type: 'any' },
|
payloadSchema: { type: 'any' },
|
||||||
units: { measure: 'volumeFlowRate', default: 'm3/h' },
|
unit: 'm3/h',
|
||||||
description: 'Push a measured outflow value into the basin balance.',
|
description: 'Push a measured outflow value into the basin balance.',
|
||||||
handler: handlers.setOutflow,
|
handler: handlers.setOutflow,
|
||||||
},
|
},
|
||||||
@@ -61,7 +61,7 @@ module.exports = [
|
|||||||
topic: 'set.demand',
|
topic: 'set.demand',
|
||||||
aliases: ['Qd'],
|
aliases: ['Qd'],
|
||||||
payloadSchema: { type: 'any' },
|
payloadSchema: { type: 'any' },
|
||||||
units: { measure: 'volumeFlowRate', default: 'm3/h' },
|
unit: 'm3/h',
|
||||||
description: 'Operator outflow demand setpoint for the station.',
|
description: 'Operator outflow demand setpoint for the station.',
|
||||||
handler: handlers.setDemand,
|
handler: handlers.setDemand,
|
||||||
},
|
},
|
||||||
|
|||||||
@@ -11,7 +11,11 @@
|
|||||||
|
|
||||||
## Topic contract
|
## Topic contract
|
||||||
|
|
||||||
The **Unit** column reflects each descriptor's `units: { measure, default }` declaration. The default unit is what the commandRegistry coerces incoming `msg.unit` values to before the handler runs.
|
The **Unit** column reflects each descriptor's declared unit (via the `unit: 'm3/h'` shorthand or the legacy `units: { measure, default }`; the measure is derived from the unit). The default unit is what the commandRegistry coerces incoming values to before the handler runs.
|
||||||
|
|
||||||
|
**Command envelope (all EVOLV nodes).** Every command shares one envelope on top of `msg.topic`:
|
||||||
|
- **Value + unit** — send `msg.payload` as a number (with optional sibling `msg.unit`) **or** as `{ value, unit }`. The registry always converts the value to the descriptor's unit before the handler; numeric strings are converted too. A missing unit assumes the descriptor default.
|
||||||
|
- **`msg.origin`** — the control authority that issued the command: `parent` (automation/parent controller, the default), `GUI` (SCADA/HMI operator), or `fysical` (physical buttons). On nodes with a control mode, the mode's `allowedSources` decides which origins are accepted; releasing control is done by changing the mode.
|
||||||
|
|
||||||
<!-- BEGIN AUTOGEN: topic-contract -->
|
<!-- BEGIN AUTOGEN: topic-contract -->
|
||||||
|
|
||||||
@@ -19,11 +23,11 @@ The **Unit** column reflects each descriptor's `units: { measure, default }` dec
|
|||||||
|---|---|---|---|---|
|
|---|---|---|---|---|
|
||||||
| `set.mode` | `changemode` | `string` | — | Switch the station between auto / manual control modes. |
|
| `set.mode` | `changemode` | `string` | — | Switch the station between auto / manual control modes. |
|
||||||
| `child.register` | `registerChild` | `string` | — | Register a child node (machine group, measurement, …) with this station. |
|
| `child.register` | `registerChild` | `string` | — | Register a child node (machine group, measurement, …) with this station. |
|
||||||
| `cmd.calibrate.volume` | `calibratePredictedVolume` | `any` | `volume` (default `m3`) | Calibrate the predicted-volume integrator to a known basin volume. |
|
| `cmd.calibrate.volume` | `calibratePredictedVolume` | any | `volume` (default `m3`) | Calibrate the predicted-volume integrator to a known basin volume. |
|
||||||
| `cmd.calibrate.level` | `calibratePredictedLevel` | `any` | `length` (default `m`) | Calibrate the predicted-volume integrator to a known basin level. |
|
| `cmd.calibrate.level` | `calibratePredictedLevel` | any | `length` (default `m`) | Calibrate the predicted-volume integrator to a known basin level. |
|
||||||
| `set.inflow` | `q_in` | `any` | `volumeFlowRate` (default `m3/h`) | Push a measured inflow value into the basin balance. |
|
| `set.inflow` | `q_in` | any | `volumeFlowRate` (default `m3/h`) | Push a measured inflow value into the basin balance. |
|
||||||
| `set.outflow` | `q_out` | `any` | `volumeFlowRate` (default `m3/h`) | Push a measured outflow value into the basin balance. |
|
| `set.outflow` | `q_out` | any | `volumeFlowRate` (default `m3/h`) | Push a measured outflow value into the basin balance. |
|
||||||
| `set.demand` | `Qd` | `any` | `volumeFlowRate` (default `m3/h`) | Operator outflow demand setpoint for the station. |
|
| `set.demand` | `Qd` | any | `volumeFlowRate` (default `m3/h`) | Operator outflow demand setpoint for the station. |
|
||||||
|
|
||||||
<!-- END AUTOGEN: topic-contract -->
|
<!-- END AUTOGEN: topic-contract -->
|
||||||
|
|
||||||
|
|||||||
Reference in New Issue