P2 wave 1: extract concerns from pumpingStation specificClass
Splits pumpingStation/src/ into focused concern modules. specificClass.js
will be slimmed to an orchestrator in P2.9 (integration); for now both
the inlined logic AND the new modules coexist so tests stay green
throughout.
src/basin/ BasinGeometry + thresholdValidator (pure)
src/measurement/ flowAggregator + measurementRouter + calibration
src/control/ levelBased + flowBased(stub) + manual + index dispatcher
src/safety/ safetyController split into dryRun + overfill rules
src/commands/ registry array + handlers (canonical names from start)
src/editor.js 260 lines of SVG basin-diagram redraw, was inline in .html
examples/standalone-demo.js was if(require.main===module) at bottom of specificClass.js
CONTRACT.md canonical inputs + outputs + emitted events
Modified:
src/specificClass.js removed the 170-line standalone demo block
pumpingStation.html oneditprepare/oneditsave delegate to editor.{init,save}
pumpingStation.js added admin endpoint serving src/editor.js
102 basic tests pass (60 new + 42 existing).
specificClass.js itself is unchanged in behaviour — integration is P2.9.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
106
test/basic/measurementRouter.basic.test.js
Normal file
106
test/basic/measurementRouter.basic.test.js
Normal file
@@ -0,0 +1,106 @@
|
||||
// Basic tests for MeasurementRouter.
|
||||
|
||||
const test = require('node:test');
|
||||
const assert = require('node:assert/strict');
|
||||
|
||||
const { MeasurementContainer, coolprop } = require('generalFunctions');
|
||||
const MeasurementRouter = require('../../src/measurement/measurementRouter');
|
||||
|
||||
// CoolProp is async-init; ensure it's warm before any pressure-conversion
|
||||
// test runs.
|
||||
test.before(async () => {
|
||||
await coolprop.init({ refrigerant: 'Water' });
|
||||
});
|
||||
|
||||
function makeBasin() {
|
||||
return {
|
||||
surfaceArea: 10,
|
||||
minVol: 2,
|
||||
maxVol: 50,
|
||||
maxVolAtOverflow: 45,
|
||||
overflowLevel: 4.5,
|
||||
outflowLevel: 0.2,
|
||||
inflowLevel: 3,
|
||||
};
|
||||
}
|
||||
|
||||
function makeMeasurements() {
|
||||
return new MeasurementContainer({
|
||||
autoConvert: true,
|
||||
preferredUnits: { flow: 'm3/s', level: 'm', volume: 'm3' },
|
||||
});
|
||||
}
|
||||
|
||||
function fakeLogger() {
|
||||
const calls = { warn: [], info: [], error: [], debug: [] };
|
||||
return {
|
||||
warn: (m) => calls.warn.push(m),
|
||||
info: (m) => calls.info.push(m),
|
||||
error: (m) => calls.error.push(m),
|
||||
debug: (m) => calls.debug.push(m),
|
||||
_calls: calls,
|
||||
};
|
||||
}
|
||||
|
||||
test('onLevelMeasurement writes volume + percent', async () => {
|
||||
const measurements = makeMeasurements();
|
||||
const basin = makeBasin();
|
||||
const router = new MeasurementRouter({ measurements, basin });
|
||||
|
||||
router.onLevelMeasurement('atequipment', 2.5, { unit: 'm', timestamp: Date.now() });
|
||||
|
||||
const lvl = measurements.type('level').variant('measured').position('atequipment').getCurrentValue('m');
|
||||
assert.ok(Math.abs(lvl - 2.5) < 1e-9);
|
||||
|
||||
const vol = measurements.type('volume').variant('measured').position('atequipment').getCurrentValue('m3');
|
||||
// 2.5 m * 10 m² = 25 m3.
|
||||
assert.ok(Math.abs(vol - 25) < 1e-9, `volume was ${vol}`);
|
||||
|
||||
const pct = measurements.type('volumePercent').variant('measured').position('atequipment').getCurrentValue('%');
|
||||
// (25 - 2) / (45 - 2) * 100 ≈ 53.488...
|
||||
assert.ok(pct > 53 && pct < 54, `percent was ${pct}`);
|
||||
});
|
||||
|
||||
test('onPressureMeasurement falls back to assumed temperature and warns', async () => {
|
||||
const measurements = makeMeasurements();
|
||||
const basin = makeBasin();
|
||||
const logger = fakeLogger();
|
||||
const router = new MeasurementRouter({ measurements, basin, logger });
|
||||
|
||||
// No temperature seeded — must fall back to assumed 15C.
|
||||
measurements.type('pressure').variant('measured').position('atequipment')
|
||||
.value(20000, Date.now(), 'Pa');
|
||||
router.onPressureMeasurement('atequipment', 20000, { unit: 'Pa', timestamp: Date.now() });
|
||||
|
||||
const warned = logger._calls.warn.some((m) => /assuming 15C|temperature/i.test(m));
|
||||
assert.ok(warned, 'expected a warn about missing temperature');
|
||||
|
||||
const assumedT = measurements.type('temperature').variant('assumed').position('atequipment')
|
||||
.getCurrentValue('K');
|
||||
assert.ok(Number.isFinite(assumedT), 'assumed temperature was not stored');
|
||||
|
||||
const lvl = measurements.type('level').variant('predicted').position('atequipment')
|
||||
.getCurrentValue('m');
|
||||
// 20000 Pa / (~999 kg/m³ * 9.80665) ≈ 2.04 m.
|
||||
assert.ok(lvl > 1.9 && lvl < 2.2, `derived level was ${lvl}`);
|
||||
});
|
||||
|
||||
test('route() dispatches by measurement type', async () => {
|
||||
const measurements = makeMeasurements();
|
||||
const basin = makeBasin();
|
||||
const router = new MeasurementRouter({ measurements, basin });
|
||||
|
||||
const handledLevel = router.route('level', 1.5, 'atequipment', { unit: 'm' });
|
||||
assert.equal(handledLevel, true);
|
||||
const lvl = measurements.type('level').variant('measured').position('atequipment').getCurrentValue('m');
|
||||
assert.ok(Math.abs(lvl - 1.5) < 1e-9);
|
||||
|
||||
// Unknown type returns false (no dispatch).
|
||||
const handledOther = router.route('flow', 0.1, 'in', {});
|
||||
assert.equal(handledOther, false);
|
||||
});
|
||||
|
||||
test('constructor rejects missing context fields', async () => {
|
||||
assert.throws(() => new MeasurementRouter({}));
|
||||
assert.throws(() => new MeasurementRouter({ measurements: makeMeasurements() }));
|
||||
});
|
||||
Reference in New Issue