title: Power-based mode
|
|||
|
|
mode: powerBased
|
|||
|
|
tier: 2
|
|||
|
|
status: placeholder
|
|||
|
|
updated: 2026-04-22
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
# Power-based mode — *Tier 2 template*
|
|||
|
|
|
|||
|
|
> **Status — not yet implemented.** Placeholder. This page documents the intended shape of a grid-aware / netcongestion-aware station.
|
|||
|
|
|
|||
|
|
## At a glance
|
|||
|
|
|
|||
|
|
| Item | Value |
|
|||
|
|
|---|---|
|
|||
|
|
| Tier | 2 — parameterised transfer function |
|
|||
|
|
| Signal driving demand | basin level (primary), **max-power budget** (clip) |
|
|||
|
|
| Secondary inputs | measured pump power, live grid-price / peak-hours signal |
|
|||
|
|
| Output | demand 0–100 % clipped so `Σ pump power ≤ maxPowerKW(t)` |
|
|||
|
|
| Thresholds adjusted at runtime? | `maxPowerKW(t)` yes — level thresholds no |
|
|||
|
|
| Use when | Grid has peak-hour tariffs or net-congestion caps |
|
|||
|
|
|
|||
|
|
## Diagram — the levelbased curve with a moving clip ceiling
|
|||
|
|
|
|||
|
|
```
|
|||
|
|
demand % ← dashed line: levelbased curve
|
|||
|
|
100 ┤ ╱ ─────── ← solid: clip at powerBudget(t)
|
|||
|
|
│ ╱ clip lowers
|
|||
|
|
│ ╱ during grid peak
|
|||
|
|
│ ╱ ─────────
|
|||
|
|
│ ╱ ╱
|
|||
|
|
│ ╱ ╱
|
|||
|
|
│ ╱ ╱
|
|||
|
|
0 ┼────────●───────●─────────────────────► level
|
|||
|
|
startLevel maxLevel
|
|||
|
|
|
|||
|
|
↑ the family of curves:
|
|||
|
|
clip=100% (grid idle),
|
|||
|
|
clip=70% (shoulder),
|
|||
|
|
clip=40% (peak).
|
|||
|
|
```
|
|||
|
|
|
|||
|
|
The *shape* stays levelbased; the *ceiling* drops when the grid is strained. That's the Tier-2 signature: same input axis, parameter shifts the curve.
|
|||
|
|
|
|||
|
|
## Inputs
|
|||
|
|
|
|||
|
|
| Signal | Where from | Role |
|
|||
|
|
|---|---|---|
|
|||
|
|
| current level | as in levelbased | primary input |
|
|||
|
|
| `config.control.powerBased.maxPowerKW` | editor, static | hard cap on station power |
|
|||
|
|
| `config.control.powerBased.powerControlMode` | `limit` / `optimize` | whether to just clip or to schedule |
|
|||
|
|
| live grid signal (future) | external topic or forecast | modulates the cap over time |
|
|||
|
|
| measured pump power | `power.measured.*` from children | real-time feedback against the cap |
|
|||
|
|
|
|||
|
|
## Threshold policy
|
|||
|
|
|
|||
|
|
Level thresholds (`minLevel`, `startLevel`, `maxLevel`) are **identical to levelbased** — they define the shape of the underlying curve. What's new is a runtime-varying ceiling `demandCap(t)` derived from the power budget.
|
|||
|
|
|
|||
|
|
`demandCap(t) = 100 × (maxPowerKW(t) / nominalStationPowerAtFull)` — where `maxPowerKW(t)` may come from config (static `limit` mode) or an external grid-price feed (dynamic).
|
|||
|
|
|
|||
|
|
## Demand formula
|
|||
|
|
|
|||
|
|
```text
|
|||
|
|
rawDemand = levelbasedDemand(level) # the underlying Tier-1 curve
|
|||
|
|
demandCap = min(100, 100 × maxPowerKW(t) / nominalStationPower)
|
|||
|
|
demand = min(rawDemand, demandCap)
|
|||
|
|
```
|
|||
|
|
|
|||
|
|
When `demandCap < rawDemand`, the mode sacrifices drainage rate to stay within power budget. Level may rise — the overfill safety layer still applies as the last line of defence.
|
|||
|
|
|
|||
|
|
## Edge cases
|
|||
|
|
|
|||
|
|
- **Peak hour with rising level.** demandCap drops faster than level rises → demand gets clipped; level approaches `overflowLevel`. If overfill safety trips, it overrides the clip (safety wins).
|
|||
|
|
- **Power signal dropout.** Fall back to static `maxPowerKW` from config; log warning.
|
|||
|
|
- **Grid exit from peak while basin is nearly full.** demandCap jumps back to 100; PID is memoryless so demand rises in one tick to match rawDemand.
|
|||
|
|
- **Measured vs predicted pump power.** Cap is enforced on predicted (decisions are made before the pump responds). Reconcile against measured for logging/diagnostics.
|
|||
|
|
|
|||
|
|
## Related
|
|||
|
|
|
|||
|
|
- [Functional description](../functional-description.md)
|
|||
|
|
- [modes/levelbased.md](levelbased.md) — Tier 1 reference (the curve that powerBased clips)
|
|||
|
|