## 1. What this node is
**monster** is an S88 Unit that runs an AQUON-scheduled flow-proportional sampling program. It aggregates measured + manual flow, blends a rain-scaled prediction, and emits a `pulse` whenever the integrated volume crosses `m³ per pulse`. Drives the physical "monsternamekast" (composite sampling cabinet) on a wastewater treatment plant.
Mirrors the `ChildRouter` declaration in `specificClass.js → configure()`. Monster only accepts `measurement` children whose `asset.type` is `flow` (or unset).
Skipped — monster has no formal state machine. The `running` boolean toggles when `_beginRun` / `_endRun` fire. See section 7 for the sampling-program sequence, which is the closest analogue.
## 11. Examples
| Tier | File | What it shows | Status |
|---|---|---|---|
| Basic | `examples/basic.flow.json` | Inject + manual flow + dashboard, no parent | ✅ in repo |
| API | `examples/monster-api-dashboard.flow.json` | dashboardAPI consumer wired in | ✅ in repo |
One screenshot per tier where helpful. PNG ≤ 200 KB under `wiki/_partial-screenshots/monster/`.
## 12. Debug recipes
| Symptom | First thing to check | Where to look |
|---|---|---|
| `pulse` never fires | Is `running` true? Check `validateFlowBounds` log — invalid bounds short-circuits the run. | `parameters/parameters.js` |
| Pulses arrive too fast / skipped | Cooldown guard active. Inspect `missedSamples` + `minSampleIntervalSec`. | `sampling/samplingProgram.js → _maybeEmitPulse` |
| `q` always zero | Measured-flow child not registered, manual flow not pushed. Watch Port 2 + `data.flow` history. | `flow/flowTracker.js` |
| `nextDate` not arming | `set.schedule` payload didn't include matching `aquonSampleName` row. | `schedule/schedule.js → regNextDate` |
| `sumRain` zero with rain input | `rainAggregator.update` ran while `running=true` (skipped). | `specificClass.js → updateRainData` |
| Bucket overfilled before `stop_time` | `m3PerPuls` rounded down; check `predFlow` vs effective `q`. | `sampling/samplingProgram.js → _beginRun` |
> Never ship `enableLog: 'debug'` in a demo — fills the container log within seconds and obscures real errors. Use only for live debugging.
## 13. When you would NOT use this node
- Use monster for **AQUON-scheduled composite sampling** on a wastewater plant. For a single grab sample on demand, fire `cmd.start` once and tear it down — monster is overkill for ad-hoc work.
- Don't use monster as a generic flow totaliser. Use a `measurement` child with the right type/variant for raw flow integration.
- Skip monster if you don't need pulse-proportional dosing — the time-mode (`flowmeter=false`) is currently informational only.
## 14. Known limitations / current issues
| # | Issue | Tracked in |
|---|---|---|
| 1 | Edge test `sampling-guards.edge.test.js` cooldown-guard case is a pre-existing failure — the cooldown skip increments `missedSamples` but the assertion expects a different timing. | `test/edge/sampling-guards.edge.test.js` |
| 2 | `set.mode` and `set.model-prediction` are reserved — handlers delegate to optional methods that don't exist yet. | `commands/handlers.js` |
| 3 | Time-only mode (`flowmeter=false`) is not exercised — the sampling program assumes a flow source. | `sampling/samplingProgram.js` |
| 4 | Sub-sample volume hard-coded at 50 mL (schema enforces `min=max=50`). | `generalFunctions/src/configs/monster.json` |