RED.nodes.registerType('machineGroupControl',{
|
2025-07-01 17:03:36 +02:00
|
|
|
category: "EVOLV",
|
2025-10-14 13:52:18 +02:00
|
|
|
color: "#50a8d9",
|
2025-07-01 17:03:36 +02:00
|
|
|
defaults: {
|
|
|
|
|
// Define default properties
|
|
|
|
|
name: { value: "" },
|
2026-03-12 16:43:29 +01:00
|
|
|
processOutputFormat: { value: "process" },
|
|
|
|
|
dbaseOutputFormat: { value: "influxdb" },
|
2025-07-01 17:03:36 +02:00
|
|
|
|
feat(mgc): editor defaults, compact status badge, mode-case fix, real example flows + dashboard
Editor (mgc.html)
- Drag-in defaults now expose mode (optimalControl) and scaling (normalized)
via dropdowns in the edit dialog. Was: no control fields in the UI at all,
so users had to send set.mode/set.scaling after deploy or live with the
hidden schema defaults.
Wire-up (src/nodeClass.js)
- buildDomainConfig now bridges the flat editor fields (mode, scaling) into
the nested schema shape (mode.current, scaling.current). Was: returned {}
so the editor's mode/scaling never reached the runtime.
Mode-case bug fix (src/specificClass.js)
- Schema enum values are camelCase (optimalControl, priorityControl) but the
runtime switch in _runDispatch matched lowercase only. With the default
config, dispatch silently fell through to the warning branch and nothing
ran. Normalise via String(this.mode).toLowerCase() so both forms work.
Status badge (src/io/output.js)
- Compacted from ~80 chars (mode | Ⓝ: 💨=Q/Qmax | ⚡=P | N machine(s)) to
~50 chars (mode | norm | Q=Q/Qmax m³/h | P=P kW | active/total x).
Drops emoji glyphs that rendered inconsistently across themes; uses the
same dot+fill convention as pumpingStation.
Output extension (src/io/output.js)
- getOutput() now also emits flowCapacityMin/Max, machineCount,
machineCountActive. Was: only group-level totals + dist-from-peak +
mode/scaling, so dashboards couldn't show capacity / active count
without subscribing to each rotatingMachine individually.
Examples
- Drop pre-refactor stubs (basic.flow.json, integration.flow.json,
edge.flow.json). They had a single MGC + inject + debug, no children,
and never dispatched anything.
- 01-Basic.json: 1 MGC + 3 rotatingMachine pumps + Setup once-fires
virtualControl + cmd.startup on all pumps via fan-out function. Numbered
driver groups for Control mode / Scaling / Operator demand. Pumps
register with MGC via Port 2 (child.register, automatic).
- 02-Dashboard.json: same plumbing + FlowFuse Dashboard 2.0 page with
Controls (mode + scaling buttons, demand slider 0–100, stop + init
buttons), Status (7 ui-text rows), Trends (3 charts: flow + capacity,
power, BEP rel %), and a raw-output ui-template dumping every Port 0
field. Fan-out function caches last-known values so deltas don't blank.
Wiki + README
- examples/README.md rewritten for the two-file set with canonical command
surface table and "what to try" recipes.
- wiki/Home.md §11 (Examples) updated; §14 #4 (TODO flow item) replaced
with the actual current limitation (no per-pump fan-out on Port 0).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-12 15:24:03 +02:00
|
|
|
// Control strategy
|
governance + unit-self-describing demand + dashboard fixes
Two governance items from the 2026-05-14 quality review:
- test/_output-manifest.md enumerates every Port 0/1/2 key MGC emits, its
source, type, range, and which tests cover it in populated/degraded states
(per .claude/rules/output-coverage.md).
- src/control/strategies.js extracts computeEqualFlowDistribution as a pure
function so the equal-flow algorithm is testable without an MGC fixture.
test/basic/equalFlowDistribution.basic.test.js (6 tests) covers all three
demand branches and pins the legacy quirk where the default branch counts
active machines but iterates priority-ordered first-N (documented in the
test so the future cleanup is a deliberate change).
Plus rolled-up session work that landed alongside:
- set.demand is now unit-self-describing ({value, unit:'m3/h'|'l/s'|'%'|...}
or bare number = %); setScaling/scaling.current removed from MGC, commands,
editor (mgc.html), specificClass.
- _optimalControl + equalFlowControl now compute eta = (Q*dP)/P_shaft rather
than Q/P, keeping the metric in the same scale as each child's cog.
- groupEfficiency.calcRelativeDistanceFromPeak returns undefined (was 1) when
pumps are homogeneous (|max-min| < 1e-9). Dashboard treats undefined as
'-' instead of showing a misleading 100% / 0% reading.
- examples/02-Dashboard.json: auto-init inject so the dashboard populates at
deploy, NCog formatter normalizes the SUM emitted by MGC by
machineCountActive, Q-H fanout trims the flat-Q tail so the H axis isn't
stretched to 40m by curve-envelope clamp points, num/pct treat null AND
undefined as no-data (closes the +null === 0 trap).
- new test/integration/dashboard-fanout.integration.test.js (17 tests),
bep-distance-demand-sweep.integration.test.js (3 tests),
group-bep-cascade.integration.test.js -- total suite now 108/108 green.
- .gitignore: wiki/test.gif (143 MB screen recording, kept locally only).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-14 22:31:25 +02:00
|
|
|
mode: { value: "optimalControl" }, // optimalControl | priorityControl | maintenance
|
feat(mgc): editor defaults, compact status badge, mode-case fix, real example flows + dashboard
Editor (mgc.html)
- Drag-in defaults now expose mode (optimalControl) and scaling (normalized)
via dropdowns in the edit dialog. Was: no control fields in the UI at all,
so users had to send set.mode/set.scaling after deploy or live with the
hidden schema defaults.
Wire-up (src/nodeClass.js)
- buildDomainConfig now bridges the flat editor fields (mode, scaling) into
the nested schema shape (mode.current, scaling.current). Was: returned {}
so the editor's mode/scaling never reached the runtime.
Mode-case bug fix (src/specificClass.js)
- Schema enum values are camelCase (optimalControl, priorityControl) but the
runtime switch in _runDispatch matched lowercase only. With the default
config, dispatch silently fell through to the warning branch and nothing
ran. Normalise via String(this.mode).toLowerCase() so both forms work.
Status badge (src/io/output.js)
- Compacted from ~80 chars (mode | Ⓝ: 💨=Q/Qmax | ⚡=P | N machine(s)) to
~50 chars (mode | norm | Q=Q/Qmax m³/h | P=P kW | active/total x).
Drops emoji glyphs that rendered inconsistently across themes; uses the
same dot+fill convention as pumpingStation.
Output extension (src/io/output.js)
- getOutput() now also emits flowCapacityMin/Max, machineCount,
machineCountActive. Was: only group-level totals + dist-from-peak +
mode/scaling, so dashboards couldn't show capacity / active count
without subscribing to each rotatingMachine individually.
Examples
- Drop pre-refactor stubs (basic.flow.json, integration.flow.json,
edge.flow.json). They had a single MGC + inject + debug, no children,
and never dispatched anything.
- 01-Basic.json: 1 MGC + 3 rotatingMachine pumps + Setup once-fires
virtualControl + cmd.startup on all pumps via fan-out function. Numbered
driver groups for Control mode / Scaling / Operator demand. Pumps
register with MGC via Port 2 (child.register, automatic).
- 02-Dashboard.json: same plumbing + FlowFuse Dashboard 2.0 page with
Controls (mode + scaling buttons, demand slider 0–100, stop + init
buttons), Status (7 ui-text rows), Trends (3 charts: flow + capacity,
power, BEP rel %), and a raw-output ui-template dumping every Port 0
field. Fan-out function caches last-known values so deltas don't blank.
Wiki + README
- examples/README.md rewritten for the two-file set with canonical command
surface table and "what to try" recipes.
- wiki/Home.md §11 (Examples) updated; §14 #4 (TODO flow item) replaced
with the actual current limitation (no per-pump fan-out on Port 0).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-12 15:24:03 +02:00
|
|
|
|
Fix stale flow cache on MGC shutdown; correct NCog physics tests
### Bug fix — stale flow cache on shutdown (specificClass.js)
When turnOffAllMachines() fires (negative demand, zero flow demand, or
safety trip), the MGC was only shutting pumps down. The pumps' last
emitted predicted flow / power stayed in the MeasurementContainer,
so the parent pumpingStation kept computing net flow from cached
non-zero values — reading the MGC as "still draining" when it wasn't.
Net: net-flow direction and safety triggers misfired during and
shortly after an MGC shutdown.
Fix: after shutting down all machines, write 0 to the predicted
flow (downstream + atEquipment) and predicted power (atEquipment)
slots so the cache reflects reality immediately.
### Correctness — async/await on shutdown (specificClass.js)
Two call sites invoked turnOffAllMachines() without awaiting it, so
the subsequent `return` raced the shutdown promises. Now awaited.
Also DRY'd one inline shutdown loop into a call to
turnOffAllMachines().
### Physics correction — NCog for centrifugal pumps (integration tests)
The previous tests asserted NCog > 0 for centrifugal pumps. That's
physically wrong: for variable-speed centrifugal pumps P ∝ n³ and
Q ∝ n, so Q/P ∝ 1/n² is monotonically decreasing with speed. Peak
efficiency (peak Q/P) is always at minimum speed → cogIndex = 0 →
NCog = 0 by the current formula.
Tests now:
- Assert NCog == 0 for all centrifugal configurations
- Assert distributeByNCog() falls back to equal distribution when
NCog == 0 (confirmed by the existing tests 4-6 that slope-based
redistribution is what actually differentiates pumps with different
BEPs — not NCog)
This matches the actual implementation; the previous tests were
asserting an idealised COG model that doesn't apply here.
### Editor hygiene (mgc.html, nodeClass.js)
- mgc.html: add missing asset-menu defaults (uuid, supplier, category,
assetType, model, unit) — brings MGC in line with rotatingMachine
and pumpingStation editor shapes.
- nodeClass.js: clear node status badge on close.
All 13 tests (basic + integration) pass.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-22 17:51:10 +02:00
|
|
|
//define asset properties
|
|
|
|
|
uuid: { value: "" },
|
|
|
|
|
supplier: { value: "" },
|
|
|
|
|
category: { value: "" },
|
|
|
|
|
assetType: { value: "" },
|
|
|
|
|
model: { value: "" },
|
|
|
|
|
unit: { value: "" },
|
|
|
|
|
|
2025-07-01 17:03:36 +02:00
|
|
|
// Logger properties
|
|
|
|
|
enableLog: { value: false },
|
|
|
|
|
logLevel: { value: "error" },
|
|
|
|
|
|
2025-09-05 16:20:22 +02:00
|
|
|
//physicalAspect
|
2025-07-01 17:03:36 +02:00
|
|
|
positionVsParent: { value: "" },
|
|
|
|
|
positionIcon: { value: "" },
|
2025-09-05 16:20:22 +02:00
|
|
|
hasDistance: { value: false },
|
|
|
|
|
distance: { value: 0 },
|
|
|
|
|
distanceUnit: { value: "m" },
|
|
|
|
|
distanceDescription: { value: "" }
|
feat(mgc): editor defaults, compact status badge, mode-case fix, real example flows + dashboard
Editor (mgc.html)
- Drag-in defaults now expose mode (optimalControl) and scaling (normalized)
via dropdowns in the edit dialog. Was: no control fields in the UI at all,
so users had to send set.mode/set.scaling after deploy or live with the
hidden schema defaults.
Wire-up (src/nodeClass.js)
- buildDomainConfig now bridges the flat editor fields (mode, scaling) into
the nested schema shape (mode.current, scaling.current). Was: returned {}
so the editor's mode/scaling never reached the runtime.
Mode-case bug fix (src/specificClass.js)
- Schema enum values are camelCase (optimalControl, priorityControl) but the
runtime switch in _runDispatch matched lowercase only. With the default
config, dispatch silently fell through to the warning branch and nothing
ran. Normalise via String(this.mode).toLowerCase() so both forms work.
Status badge (src/io/output.js)
- Compacted from ~80 chars (mode | Ⓝ: 💨=Q/Qmax | ⚡=P | N machine(s)) to
~50 chars (mode | norm | Q=Q/Qmax m³/h | P=P kW | active/total x).
Drops emoji glyphs that rendered inconsistently across themes; uses the
same dot+fill convention as pumpingStation.
Output extension (src/io/output.js)
- getOutput() now also emits flowCapacityMin/Max, machineCount,
machineCountActive. Was: only group-level totals + dist-from-peak +
mode/scaling, so dashboards couldn't show capacity / active count
without subscribing to each rotatingMachine individually.
Examples
- Drop pre-refactor stubs (basic.flow.json, integration.flow.json,
edge.flow.json). They had a single MGC + inject + debug, no children,
and never dispatched anything.
- 01-Basic.json: 1 MGC + 3 rotatingMachine pumps + Setup once-fires
virtualControl + cmd.startup on all pumps via fan-out function. Numbered
driver groups for Control mode / Scaling / Operator demand. Pumps
register with MGC via Port 2 (child.register, automatic).
- 02-Dashboard.json: same plumbing + FlowFuse Dashboard 2.0 page with
Controls (mode + scaling buttons, demand slider 0–100, stop + init
buttons), Status (7 ui-text rows), Trends (3 charts: flow + capacity,
power, BEP rel %), and a raw-output ui-template dumping every Port 0
field. Fan-out function caches last-known values so deltas don't blank.
Wiki + README
- examples/README.md rewritten for the two-file set with canonical command
surface table and "what to try" recipes.
- wiki/Home.md §11 (Examples) updated; §14 #4 (TODO flow item) replaced
with the actual current limitation (no per-pump fan-out on Port 0).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-12 15:24:03 +02:00
|
|
|
|
2025-07-01 17:03:36 +02:00
|
|
|
},
|
2025-05-14 08:23:29 +02:00
|
|
|
inputs:1,
|
2025-07-01 17:03:36 +02:00
|
|
|
outputs:3,
|
|
|
|
|
inputLabels: ["Input"],
|
|
|
|
|
outputLabels: ["process", "dbase", "parent"],
|
2025-10-14 13:52:18 +02:00
|
|
|
icon: "font-awesome/fa-cogs",
|
2025-05-14 08:23:29 +02:00
|
|
|
|
2025-07-01 17:03:36 +02:00
|
|
|
label: function () {
|
2026-03-11 11:12:52 +01:00
|
|
|
return (this.positionIcon || "") + " machineGroup";
|
2025-07-01 17:03:36 +02:00
|
|
|
},
|
2025-05-14 08:23:29 +02:00
|
|
|
oneditprepare: function() {
|
2025-07-01 17:03:36 +02:00
|
|
|
// Initialize the menu data for the node
|
|
|
|
|
const waitForMenuData = () => {
|
|
|
|
|
if (window.EVOLV?.nodes?.machineGroupControl?.initEditor) {
|
|
|
|
|
window.EVOLV.nodes.machineGroupControl.initEditor(this);
|
|
|
|
|
} else {
|
|
|
|
|
setTimeout(waitForMenuData, 50);
|
2025-05-14 08:23:29 +02:00
|
|
|
}
|
2025-07-01 17:03:36 +02:00
|
|
|
};
|
|
|
|
|
// Wait for the menu data to be ready before initializing the editor
|
|
|
|
|
waitForMenuData();
|
2025-05-14 08:23:29 +02:00
|
|
|
|
|
|
|
|
},
|
|
|
|
|
oneditsave: function(){
|
|
|
|
|
const node = this;
|
|
|
|
|
|
2025-07-01 17:03:36 +02:00
|
|
|
// Validate logger properties using the logger menu
|
2025-07-31 09:10:34 +02:00
|
|
|
if (window.EVOLV?.nodes?.machineGroupControl?.loggerMenu?.saveEditor) {
|
|
|
|
|
success = window.EVOLV.nodes.machineGroupControl.loggerMenu.saveEditor(node);
|
2025-05-14 08:23:29 +02:00
|
|
|
}
|
|
|
|
|
|
2025-07-01 17:03:36 +02:00
|
|
|
// save position field
|
2025-07-31 09:10:34 +02:00
|
|
|
if (window.EVOLV?.nodes?.machineGroupControl?.positionMenu?.saveEditor) {
|
|
|
|
|
window.EVOLV.nodes.machineGroupControl.positionMenu.saveEditor(this);
|
2025-07-01 17:03:36 +02:00
|
|
|
}
|
|
|
|
|
|
2025-05-14 08:23:29 +02:00
|
|
|
}
|
|
|
|
|
});
|
|
|
|
|
|
|
|
|
|
</script>
|
|
|
|
|
|
|
|
|
|
<script type="text/html" data-template-name="machineGroupControl">
|
|
|
|
|
|
feat(mgc): editor defaults, compact status badge, mode-case fix, real example flows + dashboard
Editor (mgc.html)
- Drag-in defaults now expose mode (optimalControl) and scaling (normalized)
via dropdowns in the edit dialog. Was: no control fields in the UI at all,
so users had to send set.mode/set.scaling after deploy or live with the
hidden schema defaults.
Wire-up (src/nodeClass.js)
- buildDomainConfig now bridges the flat editor fields (mode, scaling) into
the nested schema shape (mode.current, scaling.current). Was: returned {}
so the editor's mode/scaling never reached the runtime.
Mode-case bug fix (src/specificClass.js)
- Schema enum values are camelCase (optimalControl, priorityControl) but the
runtime switch in _runDispatch matched lowercase only. With the default
config, dispatch silently fell through to the warning branch and nothing
ran. Normalise via String(this.mode).toLowerCase() so both forms work.
Status badge (src/io/output.js)
- Compacted from ~80 chars (mode | Ⓝ: 💨=Q/Qmax | ⚡=P | N machine(s)) to
~50 chars (mode | norm | Q=Q/Qmax m³/h | P=P kW | active/total x).
Drops emoji glyphs that rendered inconsistently across themes; uses the
same dot+fill convention as pumpingStation.
Output extension (src/io/output.js)
- getOutput() now also emits flowCapacityMin/Max, machineCount,
machineCountActive. Was: only group-level totals + dist-from-peak +
mode/scaling, so dashboards couldn't show capacity / active count
without subscribing to each rotatingMachine individually.
Examples
- Drop pre-refactor stubs (basic.flow.json, integration.flow.json,
edge.flow.json). They had a single MGC + inject + debug, no children,
and never dispatched anything.
- 01-Basic.json: 1 MGC + 3 rotatingMachine pumps + Setup once-fires
virtualControl + cmd.startup on all pumps via fan-out function. Numbered
driver groups for Control mode / Scaling / Operator demand. Pumps
register with MGC via Port 2 (child.register, automatic).
- 02-Dashboard.json: same plumbing + FlowFuse Dashboard 2.0 page with
Controls (mode + scaling buttons, demand slider 0–100, stop + init
buttons), Status (7 ui-text rows), Trends (3 charts: flow + capacity,
power, BEP rel %), and a raw-output ui-template dumping every Port 0
field. Fan-out function caches last-known values so deltas don't blank.
Wiki + README
- examples/README.md rewritten for the two-file set with canonical command
surface table and "what to try" recipes.
- wiki/Home.md §11 (Examples) updated; §14 #4 (TODO flow item) replaced
with the actual current limitation (no per-pump fan-out on Port 0).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-12 15:24:03 +02:00
|
|
|
<h3>Control strategy</h3>
|
|
|
|
|
<div class="form-row">
|
|
|
|
|
<label for="node-input-mode"><i class="fa fa-cogs"></i> Mode</label>
|
|
|
|
|
<select id="node-input-mode" style="width:60%;">
|
|
|
|
|
<option value="optimalControl">optimalControl — pick the best valid pump combination by BEP-gravitation / NCog</option>
|
|
|
|
|
<option value="priorityControl">priorityControl — sequential equal-flow control by priority list</option>
|
|
|
|
|
<option value="maintenance">maintenance — monitoring only, no dispatch</option>
|
|
|
|
|
</select>
|
|
|
|
|
</div>
|
governance + unit-self-describing demand + dashboard fixes
Two governance items from the 2026-05-14 quality review:
- test/_output-manifest.md enumerates every Port 0/1/2 key MGC emits, its
source, type, range, and which tests cover it in populated/degraded states
(per .claude/rules/output-coverage.md).
- src/control/strategies.js extracts computeEqualFlowDistribution as a pure
function so the equal-flow algorithm is testable without an MGC fixture.
test/basic/equalFlowDistribution.basic.test.js (6 tests) covers all three
demand branches and pins the legacy quirk where the default branch counts
active machines but iterates priority-ordered first-N (documented in the
test so the future cleanup is a deliberate change).
Plus rolled-up session work that landed alongside:
- set.demand is now unit-self-describing ({value, unit:'m3/h'|'l/s'|'%'|...}
or bare number = %); setScaling/scaling.current removed from MGC, commands,
editor (mgc.html), specificClass.
- _optimalControl + equalFlowControl now compute eta = (Q*dP)/P_shaft rather
than Q/P, keeping the metric in the same scale as each child's cog.
- groupEfficiency.calcRelativeDistanceFromPeak returns undefined (was 1) when
pumps are homogeneous (|max-min| < 1e-9). Dashboard treats undefined as
'-' instead of showing a misleading 100% / 0% reading.
- examples/02-Dashboard.json: auto-init inject so the dashboard populates at
deploy, NCog formatter normalizes the SUM emitted by MGC by
machineCountActive, Q-H fanout trims the flat-Q tail so the H axis isn't
stretched to 40m by curve-envelope clamp points, num/pct treat null AND
undefined as no-data (closes the +null === 0 trap).
- new test/integration/dashboard-fanout.integration.test.js (17 tests),
bep-distance-demand-sweep.integration.test.js (3 tests),
group-bep-cascade.integration.test.js -- total suite now 108/108 green.
- .gitignore: wiki/test.gif (143 MB screen recording, kept locally only).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-14 22:31:25 +02:00
|
|
|
<p style="margin-top:8px;color:#666;font-size:11px;">
|
|
|
|
|
Demand is self-describing per <code>set.demand</code> message: a bare number is
|
|
|
|
|
treated as % of group capacity; <code>{value, unit}</code> with a flow unit
|
|
|
|
|
(<code>m3/h</code>, <code>l/s</code>, <code>m3/s</code>, …) is dispatched
|
|
|
|
|
in absolute terms. Negative value stops all pumps.
|
|
|
|
|
</p>
|
feat(mgc): editor defaults, compact status badge, mode-case fix, real example flows + dashboard
Editor (mgc.html)
- Drag-in defaults now expose mode (optimalControl) and scaling (normalized)
via dropdowns in the edit dialog. Was: no control fields in the UI at all,
so users had to send set.mode/set.scaling after deploy or live with the
hidden schema defaults.
Wire-up (src/nodeClass.js)
- buildDomainConfig now bridges the flat editor fields (mode, scaling) into
the nested schema shape (mode.current, scaling.current). Was: returned {}
so the editor's mode/scaling never reached the runtime.
Mode-case bug fix (src/specificClass.js)
- Schema enum values are camelCase (optimalControl, priorityControl) but the
runtime switch in _runDispatch matched lowercase only. With the default
config, dispatch silently fell through to the warning branch and nothing
ran. Normalise via String(this.mode).toLowerCase() so both forms work.
Status badge (src/io/output.js)
- Compacted from ~80 chars (mode | Ⓝ: 💨=Q/Qmax | ⚡=P | N machine(s)) to
~50 chars (mode | norm | Q=Q/Qmax m³/h | P=P kW | active/total x).
Drops emoji glyphs that rendered inconsistently across themes; uses the
same dot+fill convention as pumpingStation.
Output extension (src/io/output.js)
- getOutput() now also emits flowCapacityMin/Max, machineCount,
machineCountActive. Was: only group-level totals + dist-from-peak +
mode/scaling, so dashboards couldn't show capacity / active count
without subscribing to each rotatingMachine individually.
Examples
- Drop pre-refactor stubs (basic.flow.json, integration.flow.json,
edge.flow.json). They had a single MGC + inject + debug, no children,
and never dispatched anything.
- 01-Basic.json: 1 MGC + 3 rotatingMachine pumps + Setup once-fires
virtualControl + cmd.startup on all pumps via fan-out function. Numbered
driver groups for Control mode / Scaling / Operator demand. Pumps
register with MGC via Port 2 (child.register, automatic).
- 02-Dashboard.json: same plumbing + FlowFuse Dashboard 2.0 page with
Controls (mode + scaling buttons, demand slider 0–100, stop + init
buttons), Status (7 ui-text rows), Trends (3 charts: flow + capacity,
power, BEP rel %), and a raw-output ui-template dumping every Port 0
field. Fan-out function caches last-known values so deltas don't blank.
Wiki + README
- examples/README.md rewritten for the two-file set with canonical command
surface table and "what to try" recipes.
- wiki/Home.md §11 (Examples) updated; §14 #4 (TODO flow item) replaced
with the actual current limitation (no per-pump fan-out on Port 0).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-12 15:24:03 +02:00
|
|
|
|
2026-03-12 16:43:29 +01:00
|
|
|
<h3>Output Formats</h3>
|
|
|
|
|
<div class="form-row">
|
|
|
|
|
<label for="node-input-processOutputFormat"><i class="fa fa-random"></i> Process Output</label>
|
|
|
|
|
<select id="node-input-processOutputFormat" style="width:60%;">
|
|
|
|
|
<option value="process">process</option>
|
|
|
|
|
<option value="json">json</option>
|
|
|
|
|
<option value="csv">csv</option>
|
|
|
|
|
</select>
|
|
|
|
|
</div>
|
|
|
|
|
<div class="form-row">
|
|
|
|
|
<label for="node-input-dbaseOutputFormat"><i class="fa fa-database"></i> Database Output</label>
|
|
|
|
|
<select id="node-input-dbaseOutputFormat" style="width:60%;">
|
|
|
|
|
<option value="influxdb">influxdb</option>
|
|
|
|
|
<option value="json">json</option>
|
|
|
|
|
<option value="csv">csv</option>
|
|
|
|
|
</select>
|
|
|
|
|
</div>
|
|
|
|
|
|
2025-07-01 17:03:36 +02:00
|
|
|
<!-- Logger fields injected here -->
|
|
|
|
|
<div id="logger-fields-placeholder"></div>
|
2025-05-14 08:23:29 +02:00
|
|
|
|
2025-07-01 17:03:36 +02:00
|
|
|
<!-- Position fields injected here -->
|
|
|
|
|
<div id="position-fields-placeholder"></div>
|
2025-05-14 08:23:29 +02:00
|
|
|
|
|
|
|
|
</script>
|
|
|
|
|
|
|
|
|
|
<script type="text/html" data-help-name="machineGroupControl">
|
|
|
|
|
<p>A machineGroupControl node</p>
|
|
|
|
|
</script>
|