fix(schemas): drop dead config — allowedActions (valve/VGC) + calculationMode (RM/valve/VGC)
Code audit across all consumers found: - `calculationMode` is declared in rotatingMachine.json, valve.json, and valveGroupControl.json schemas but NEVER read by any code. Pure dead config — entered values are silently discarded. Removed from all three. - `allowedActions` is declared in valve.json and valveGroupControl.json but their `flowController.handleInput` only calls `isValidSourceForMode`, never `isValidActionForMode`. The schema would invite users to configure action allow-lists that never gate anything. Removed from both. Kept in `rotatingMachine.json` and `machineGroupControl.json` where the action allow-list IS enforced (specificClass / handlers / strategies). Schema fixes only — no runtime behaviour changes. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -459,27 +459,6 @@
|
||||
"description": "Predefined sequences of states for the machine."
|
||||
|
||||
},
|
||||
"calculationMode": {
|
||||
"default": "medium",
|
||||
"rules": {
|
||||
"type": "enum",
|
||||
"values": [
|
||||
{
|
||||
"value": "low",
|
||||
"description": "Calculations run at fixed intervals (time-based)."
|
||||
},
|
||||
{
|
||||
"value": "medium",
|
||||
"description": "Calculations run when new setpoints arrive or measured changes occur (event-driven)."
|
||||
},
|
||||
{
|
||||
"value": "high",
|
||||
"description": "Calculations run on all event-driven info, including every movement."
|
||||
}
|
||||
],
|
||||
"description": "The frequency at which calculations are performed."
|
||||
}
|
||||
},
|
||||
"flowNumber": {
|
||||
"default": 1,
|
||||
"rules": {
|
||||
|
||||
@@ -205,47 +205,6 @@
|
||||
"description": "The operational mode of the machine."
|
||||
}
|
||||
},
|
||||
"allowedActions":{
|
||||
"default":{},
|
||||
"rules": {
|
||||
"type": "object",
|
||||
"schema":{
|
||||
"auto": {
|
||||
"default": ["statusCheck", "execMovement", "execSequence", "emergencyStop"],
|
||||
"rules": {
|
||||
"type": "set",
|
||||
"itemType": "string",
|
||||
"description": "Actions allowed in auto mode."
|
||||
}
|
||||
},
|
||||
"virtualControl": {
|
||||
"default": ["statusCheck", "execMovement", "execSequence", "emergencyStop"],
|
||||
"rules": {
|
||||
"type": "set",
|
||||
"itemType": "string",
|
||||
"description": "Actions allowed in virtualControl mode."
|
||||
}
|
||||
},
|
||||
"fysicalControl": {
|
||||
"default": ["statusCheck", "emergencyStop"],
|
||||
"rules": {
|
||||
"type": "set",
|
||||
"itemType": "string",
|
||||
"description": "Actions allowed in fysicalControl mode."
|
||||
}
|
||||
},
|
||||
"maintenance": {
|
||||
"default": ["statusCheck"],
|
||||
"rules": {
|
||||
"type": "set",
|
||||
"itemType": "string",
|
||||
"description": "Actions allowed in maintenance mode."
|
||||
}
|
||||
}
|
||||
},
|
||||
"description": "Information about valid command sources recognized by the machine."
|
||||
}
|
||||
},
|
||||
"allowedSources":{
|
||||
"default": {},
|
||||
"rules": {
|
||||
@@ -342,27 +301,6 @@
|
||||
},
|
||||
"description": "Predefined sequences of states for the machine."
|
||||
|
||||
},
|
||||
"calculationMode": {
|
||||
"default": "medium",
|
||||
"rules": {
|
||||
"type": "enum",
|
||||
"values": [
|
||||
{
|
||||
"value": "low",
|
||||
"description": "Calculations run at fixed intervals (time-based)."
|
||||
},
|
||||
{
|
||||
"value": "medium",
|
||||
"description": "Calculations run when new setpoints arrive or measured changes occur (event-driven)."
|
||||
},
|
||||
{
|
||||
"value": "high",
|
||||
"description": "Calculations run on all event-driven info, including every movement."
|
||||
}
|
||||
],
|
||||
"description": "The frequency at which calculations are performed."
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@@ -176,47 +176,6 @@
|
||||
"description": "The operational mode of the valveGroupControl."
|
||||
}
|
||||
},
|
||||
"allowedActions":{
|
||||
"default":{},
|
||||
"rules": {
|
||||
"type": "object",
|
||||
"schema":{
|
||||
"auto": {
|
||||
"default": ["statusCheck", "execSequence", "emergencyStop", "valvePositionChange", "totalFlowChange", "valveDeltaPchange"],
|
||||
"rules": {
|
||||
"type": "set",
|
||||
"itemType": "string",
|
||||
"description": "Actions allowed in auto mode."
|
||||
}
|
||||
},
|
||||
"virtualControl": {
|
||||
"default": ["statusCheck", "execSequence", "emergencyStop", "valvePositionChange", "totalFlowChange", "valveDeltaPchange"],
|
||||
"rules": {
|
||||
"type": "set",
|
||||
"itemType": "string",
|
||||
"description": "Actions allowed in virtualControl mode."
|
||||
}
|
||||
},
|
||||
"fysicalControl": {
|
||||
"default": ["statusCheck", "emergencyStop"],
|
||||
"rules": {
|
||||
"type": "set",
|
||||
"itemType": "string",
|
||||
"description": "Actions allowed in fysicalControl mode."
|
||||
}
|
||||
},
|
||||
"maintenance": {
|
||||
"default": ["statusCheck"],
|
||||
"rules": {
|
||||
"type": "set",
|
||||
"itemType": "string",
|
||||
"description": "Actions allowed in maintenance mode."
|
||||
}
|
||||
}
|
||||
},
|
||||
"description": "Information about valid command sources recognized by the valve."
|
||||
}
|
||||
},
|
||||
"allowedSources":{
|
||||
"default": {},
|
||||
"rules": {
|
||||
@@ -346,26 +305,5 @@
|
||||
},
|
||||
"description": "Predefined sequences of states for the valveGroupControl."
|
||||
|
||||
},
|
||||
"calculationMode": {
|
||||
"default": "medium",
|
||||
"rules": {
|
||||
"type": "enum",
|
||||
"values": [
|
||||
{
|
||||
"value": "low",
|
||||
"description": "Calculations run at fixed intervals (time-based)."
|
||||
},
|
||||
{
|
||||
"value": "medium",
|
||||
"description": "Calculations run when new setpoints arrive or measured changes occur (event-driven)."
|
||||
},
|
||||
{
|
||||
"value": "high",
|
||||
"description": "Calculations run on all event-driven info, including every movement."
|
||||
}
|
||||
],
|
||||
"description": "The frequency at which calculations are performed."
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue