Some checks failed
CI / lint-and-test (push) Has been cancelled
Submodule bumps land the deadlock fix (state.js residue unpark + MGC optimalControl dispatch reorder) and pumpingStation stopLevel hysteresis. - Renames examples/pumpingstation-3pumps-dashboard → pumpingstation-complete-example with regenerated flow.json. New dashboard groups, demand-broadcast wiring, S88 placement rule applied, ui-chart trend-split and link-channel naming follow .claude/rules/node-red-flow-layout.md. - New cross-node test harness under test/: end-to-end-pumpingstation drives PS + MGC + 3 pumps + physics simulator end-to-end and verifies the ~5/15 min cycle. - Adds Grafana provisioning dashboards (pumping-station.json) and a helper sync-example.sh script for export/import to live Node-RED. - Docker entrypoint + settings + compose tweaks for the persistent user dir layout used by the demo. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
1.4 KiB
1.4 KiB
EVOLV cross-node test harness
This folder hosts end-to-end tests that wire multiple EVOLV domain classes together the same way Node-RED would, but in pure Node.js so the simulation runs deterministically and every internal value is inspectable.
Scope rule. Tests that exercise a single node's behaviour live in that
node's submodule under nodes/<name>/test/. Tests here cross node
boundaries — they instantiate pumpingStation + machineGroupControl +
multiple rotatingMachines together and drive the wired graph.
Examples of what belongs where:
| Concern | Lives in |
|---|---|
| MGC optimizer combination choice for a given demand | nodes/machineGroupControl/test/integration/optimizer-combination-choice.integration.test.js |
| Pump curve interpolation across head values | nodes/rotatingMachine/test/integration/... |
| PS hysteresis logic with mocked groups | nodes/pumpingStation/test/integration/shifted-ramp-end-to-end.test.js |
| Whole plant: PS basin level + MGC dispatch + 3 pumps + physics simulator | test/end-to-end-pumpingstation.test.js (this folder) |
Run:
node --test test/end-to-end-pumpingstation.test.js
The harness in lib/wiring.js builds the parent-child relationships
Node-RED would build via registerChild, lets you advance a controllable
clock, and lib/recorder.js records every measurement / state / demand
event into a flat trace.