# Decision: Unit-Anchor Rollout Phase 1 (MachineGroup, PumpingStation, Valve, ValveGroupControl)
- Date: 2026-02-24
- Scope:
- `nodes/machineGroupControl/src/nodeClass.js`
- `nodes/machineGroupControl/src/specificClass.js`
- `nodes/pumpingStation/src/nodeClass.js`
- `nodes/pumpingStation/src/specificClass.js`
- `nodes/valve/src/nodeClass.js`
- `nodes/valve/src/specificClass.js`
- `nodes/valveGroupControl/src/nodeClass.js`
- `nodes/valveGroupControl/src/specificClass.js`
## Context
After adopting canonical-unit anchoring in `rotatingMachine`, adjacent controller nodes still mixed local units, unitless writes, and implicit conversions. That left cross-node behavior sensitive to registration order and source-unit assumptions.
## Decision
1. Apply the same canonical storage policy per node:
- internal storage in canonical units (`Pa`, `m3/s`, `W`, `K` where relevant),
- preferred/output units for operator-facing status and output payloads.
2. Enable strict measurement ingress discipline on migrated nodes:
- `strictUnitValidation: true`,
- `throwOnInvalidUnit: true`,
- required unit for physically dimensional types (`flow`, `pressure`, `power`, `temperature`, and node-specific equivalents).
3. Replace unitless runtime writes/reads with explicit-unit helpers in each nodes domain class, including child-machine/child-valve interactions.
## Consequences
- Cross-node calculations now run against a deterministic unit anchor in phase-1 nodes.
- Status/output values remain in preferred/output units, while internal math stays canonical.
- Legacy paths that send dimensional values without units now fail fast instead of silently coercing.
## Rollback Notes
- Revert the eight files listed in scope.
- Restore previous `MeasurementContainer` initialization (non-canonical, non-strict behavior) in each node.
- Remove helper-based explicit unit reads/writes and revert to prior direct chain usage.